Plan Review Notes
Plan Review Notes For Permit 20071019
Permit Number 20071019
Review Stop B
Sequence Number 2
Notes
Date Text
2020-08-19 06:58:28****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. THE CALCULATIONS FOR THE FLAT DECK SPECIFY 8"
 SPACING IN THE FIELD, 16" IN ZONE 2, 10" IN ZONE 3. THE
 ENGINEERING DOES NOT SPECIFY THE NUMBER OF ROWS
 REQUIRED FOR ZONES 2 AND 3. REVISE ENGINEERING TO
 SPECIFY NUMBER OF ROWS FOR EACH ZONE, AND IF THE
 FASTENING FOR ZONES 2 AND 3 ARE NOT REVISED, PROVIDE
 CALCULATIONS, FBC B 1609.
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved