| Plan Review Notes For Permit 20071019 |
| Permit Number |
20071019 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2020-08-19 06:58:28 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. THE CALCULATIONS FOR THE FLAT DECK SPECIFY 8" | | | SPACING IN THE FIELD, 16" IN ZONE 2, 10" IN ZONE 3. THE | | | ENGINEERING DOES NOT SPECIFY THE NUMBER OF ROWS | | | REQUIRED FOR ZONES 2 AND 3. REVISE ENGINEERING TO | | | SPECIFY NUMBER OF ROWS FOR EACH ZONE, AND IF THE | | | FASTENING FOR ZONES 2 AND 3 ARE NOT REVISED, PROVIDE | | | CALCULATIONS, FBC B 1609. | | | | | | |
|