2020-09-01 16:38:12WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070750
 ADD: 515 CLEMATIS ST.
 CONT: NELSON CONSTRUCTION GC, INC.
 TEL: 305-331-1400
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. SEPT. 01/2020
 ACTION: DENIED
  
 1) THE SUBMITTED CONTRACT VALUE OF $185,482.00 IS FOR
 LABOR AND MATERIALS FOR THE PROJECT AS SEEN IN THE
 CONTRACT. WHAT THE CONTRACT DOES NOT INCLUDE IS THE
 DESIGN TEAM CONTRACT WITH THE OWNER. THIS VALUE IS ALSO
 TO BE INCLUDED IN THE TOTAL COST OF THE PROJECT.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION 109.3*
 BUILDING PERMIT VALUATION. IF, IN THE OPINION OF THE
 BUILDING OFFICIAL, THE CLAIMED VALUATION OF BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS, MECHANICAL, OR
 PLUMBING SYSTEMS APPEARS TO BE UNDER ESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE
 MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS.
 WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING
 PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE
 QUALIFIER AND OWNER AND BRINGS IN THE LISTED
 SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE
 QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND
 LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE
 FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN
 LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR
 EACH PERMIT.
 2) SHEET A-1,SITE PLAN, DEMO & LIFE SAFETY LEGEND.
 2A)LAST KNOWN USE FOR THIS BUILDING? WE HAVE NO
 LICENSING FOR THIS BUILDING AND PALM BEACH COUNTY DOES
 NOT EVEN HAVE THE BACK BUILDING ON THE TAX ROLES! ONLY
 THE FRONT BUILDING. THE LEVEL II ALTERATION DOES NOT
 FIT AS WELL AS LEVEL III LIMITED STRUCTURAL
 ALTERATIONS. 907.4.4 OF THE EXISTING BUILDING CODE.
 THIS SECTION REFERS YOU BACK TO 807.5 EXIST. BUILD
 CODE. IT APPEARS WITH THE NOTES ON THE PLANS THE
 DESIGNER OF RECORD IS ALREADY TRYING TO COMPLY WITH
 SECTION 807.6 VOLUNTARY LATERAL FORCE RESISTING SYSTEM
 ALTERATIONS WITH THE ANCHORING OF THE ROOF FRAMING
 MEMBERS TO THE EXISTING TIE BEAM.
 2B) THIS BUILDING DOES QUALIFY AS A HISTORICAL
 BUILDING. HISTORIC PRESERVATION HAS ALREADY C COMMENTED
 THAT THE EXTERIOR OF THE BUILDING IS TO STAY BLOCK NO
 STUCCO. PLEASE PROVIDE HOW THE BLOCK WALL WILL BE
 DESIGNED AND CONSTRUCTED IN SUCH A MANNER AS TO PREVENT
 THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY
 PROVIDING A WATER RESISTIVE BARRIER? 2017 FBC-B SECTION
 1403.2 WEATHER PROTECTION.
 2C) THE PLANS ARE SILENT AS TO WHAT EXCEPTIONS THE
 DESIGNER IS TAKING FOR A HISTORIC BUILDING? 107.2.1.2.
 ADDITIONAL INFORMATION IS REQUIRED.
 2D) NOTE # 8 INDICATES THE BUILDING IS 2434.05 SQ. FT.
 / 100 = 24.34 OCCUPANT. PLEASE NOTE IN THE 2017 FBC-B
 TABLE 1004.1.2 DOES DIVIDE BY AN OCCUPANT LOAD FACTOR
 OF 100 THE RESULT 24.34 OCCUPANTS, YOU ALWAYS ROUND UP
 TO THE NET WHOLE OCCUPANT, BOAFS INFORMAL
 INTERPRETATION AND 2015 IBC- COMMENTARY.
 2E) NOTE # 9 INDICATES THE BUILDING CONSTRUCTION TYPE
 AS III. PLEASE PROVIDE IF THE MINIMUM BUILDING TYPE IS
 EITHER III-A OR III-B. TABLES 504.3, TABLE 504.4, TABLE
 506.2, TABLE 601 & TABLE 602 OF THE 2017 FBC-B. TABLE
 602, 0-5 FEET REQUIRES A 1 HOUR RATED WALL FOR BUSINESS
 OCCUPANCY.
 2F) EAST PROPERTY LINE NOTE NUMBER 12 INDICATES THE
 CUTTING IN THE WALL A NEW EXTERIOR DOORWAY. SHEET A-2
 ON THE FLOOR PLAN EAST WALL THE NEW OUTSWING DOOR IS
 LABELED E. PLEASE NOTE THAT DOORS & WINDOWS SHALL NOT
 OPEN OR PROJECT INTO THE PUBLIC RIGHT OF WAY. 3202.2 OF
 THE 2017 FBC-B ALSO SEE TABLE 705.8 OPENING PROECTIVES.
 2G) NORTH LINE WALL, PLEASE PROVIDE AT WHAT PERCENTAGE
 OF WALL OPENINGS IS PROPOSED & IN CONFORMANCE WITH
 TABLE 705.8. UNPROTECTED OPENINGS.
 2H) THE WEST WALL OF THE STRUCTURE, PLEASE PROVIDE AT
 WHAT PERCENTAGE OF WALL OPENINGS IS PROPOSED AND IN
 CONFORMANCE WITH TABLE 705.8 UNPROTECTED OPENINGS.
 2I) THE SOUTH WALL OF THE STRUCTURE WILL NEED TO USE AN
 ASSUMED PROPERTY LINE BETWEEN STRUCTURES TO SEE WHAT
 PERCENTAGE OF WALL OPENINGS WILL BE IN COMPLIANCE FOR
 BOTH STRUCTURES. TABLE 705.8 UNPROTECTED OPENINGS.
 3) SHEET A-3 SHOWS THE ELEVATIONS OF THE BUILDING WITH
 SERVICE LOADS (VASD) FOR THE COMPONENTS AND CLADDING
 BUT DOES NOT PROVIDE THE WIND DESIGN CRITERIA.
 2017 FBC-B 1603.1.4 WIND DESIGN DATA. THE FOLLOWING
 INFORMATION RELATED TO WIND LOADS SHALL BE SHOWN,
 REGARDLESS OF WHETHER WIND LOADS GOVERN THE DESIGN OF
 THE LATERAL FORCE-RESISTING SYSTEM OF THE STRUCTURE:
  
 3.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 3.2. RISK CATEGORY.
  
 3.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-10 TABLE 30.3.1.
  
 3.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 3.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 3.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING.. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
 4) 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, ROOF TOP VENTILATORS
 (G) PRE-ENGINEERED A/C STANDS
  
 5A) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5B) DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 5C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 6) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN
 ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM
 LOADS AND SPACING USED IN THE TESTS.
  
 7A) SHEET A-3 THE WEST ELEVATIONS SHOW THE OVERFLOW
 SCUPPERS AND COLLECTOR HEADS AS WELL AS THE SECONDARY
 EMERGENCY OVERFLOW DRAINS. PLEASE NOTE THAT BOTH THE
 OVERFLOW SCUPPERS AND SECONDARY OVERFLOW SCUPPERS ARE
 DEPICTED AT THE SAME HEIGHT. THE SECONDARY OVERFLOW
 SCUPPERS SHOULD BE IN COMPLIANCE WITH SECTION 1503.4.2
 OF THE FBC-B, 2 TO 4 INCHES HIGHER THAN THE OVERFLOWS.
  
 7B) THE SECOND ISSUE WITH THE EMERGENCY OVERFLOWS AS
 DRAWN IS THERE LOCATION. WHAT IS NOT VISIBLE ON THE
 VERTICAL PLAN IS THE CRICKETS BACK OF THE PROPOSED
 PARAPET. AT THE SHOWN HEIGHT THEY WILL BE BENEATH THE
 CRICKETS. 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED
 TO ACHIEVE CODE COMPLIANCE.
  
 7C) THE ROOF PLAN A2 SHOWS THE ROOF SLOPING TO THE WEST
 AND THE PROPOSED CRICKETS. WHAT THE ROOF DRAINAGE PLAN
 IS MISSING IS THE RAINFALL RATE TO CALCULATE THE
 DRAINAGE FOR THE SCUPPERS, AND SECONDARY EMERGENCY
 OVERFLOW SCUPPERS. 2017 FBC-B 1503.4 ROOF DRAINAGE AND
 DRAIN LEADERS AND CONDUCTORS SHALL BE SIZED IN
 ACCORDANCE WITH 1106 AND 1107 AS APPLICABLE OF THE
 FLORIDA BUILDING CODE, PLUMBING, CHAPTER 11.
  
 7D) ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST 1 FOOT
 AWAY FROM THE STRUCTURE SIDEWALKS, WHETHER BY
 UNDERGROUND PIPING, TAIL EXTENSIONS OR SPLASH BLOCKS,
 2017 FBC-B 1503.7.
  
 8) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
2020-09-01 15:25:1209/01/20 IN REVIEW. J W.