| 2020-09-23 08:56:34 | ALTERATION LEVEL III |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| | AMENDMENTS |
| | |
| | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| | 1) DRAWING S2.0 SHOWS "EXISTING ROOFING SYSTEM TO |
| | REMAIN - YET YOU HAVE ROOFING SYSTEMS UPLOADED TO |
| | PROJECTDOX. |
| | 2) PLEASE PROVIDE DETAILS OR A STATEMENT ON THE DRAWING |
| | ON HOW AND TO WHAT EXTENT YOU WILL BE USING TO COMPLY |
| | WITH FBC EXISTING BUILDING 706.8 |
| | WHEN A ROOF COVERING ON AN EXISTING SITE-BUILT |
| | SINGLEFAMILY RESIDENTIAL STRUCTURE IS REMOVED AND |
| | REPLACED ON A BUILDING THAT IS LOCATED IN THE |
| | WIND-BORNE DEBRIS REGION AS DEFINED IN THE FLORIDA |
| | BUILDING CODE, BUILDING AND THAT HAS AN INSURED VALUE |
| | OF $300,000 OR MORE OR, IF THE BUILDING IS UNINSURED OR |
| | FOR WHICH DOCUMENTATION OF INSURED VALUE IS NOT |
| | PRESENTED, HAS A JUST VALUATION FOR THE STRUCTURE FOR |
| | PURPOSES OF AD VALOREM TAXATION OF $300,000 OR MORE: |
| | (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS |
| | REQUIRED BY SECTION 706.8.1. |
| | (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION |
| | SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN |
| | THE COST OF REROOFING. |
| | 3) PLEASE SHOW THE ROOF WIND DESIGN PRESSURES ON THE |
| | DRAWING. (ZONES ARE SHOWN BUT THE PRESSURES ARE NOT). |
| | 4) PLEASE SHOW THE ROOF SLOPES. |
| | 5) MIAMI DADE NOA 19-0311.04 IS A ROOFING SYSTEM - NOT |
| | AN UNDERLAYMENT - IS THERE A FLAT ROOF TO BE REROOFED? |