| 2020-07-28 11:40:12 | 1ST REVIEW FBC-2017 PLUMBING |
| | PERMIT- 20070205 |
| | 7/28/2020 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET A020 AND OTHER ARCHITECTURAL PLANS SHOW ACCESS |
| | TO THE PUBLIC RESTROOM IS THROUGH THE STORAGE ROOM |
| | WHICH IS NOT PERMITTED PER SECTION 403.3.1 FBC P. |
| | |
| | 2) SHEET A030 ACCESSIBILITY: THE SINGLE OCCUPANCY |
| | TOILET DETAIL IS NOT IN COMPLIANCE FOR REQUIRED CLEAR |
| | FLOOR SPACES AND DOES NOT MATCH THE FLOOR PLANS. |
| | PROVIDE AN FBC ACC COMPLIANT, ENLARGED, SITE SPECIFIC, |
| | DIMENSIONED REST ROOM DRAWING INDICATING: |
| | A) CLEAR FLOOR SPACE DIMENSION FOR THE WATER CLOSET- |
| | SECTION 604.3 |
| | B) CLEAR FLOOR SPACE DIMENSION FOR THE LAVATORY- |
| | SECTION 606.2 |
| | C) CENTERLINE OF THE WATER CLOSET FROM THE SIDE WALL - |
| | SECTION 604.2. |
| | D) TURNING CIRCLE DIAMETER- SECTION 304.3. |
| | E) DOOR OPENING DIMENSION AND DOOR SWING INTO THE ROOM- |
| | SECTION 603.2.3. |
| | F) GRAB LOCATIONS AND LENGTHS- SECTION 604.5 |
| | |
| | 3) SHEET A030: CORRECT THESE ELEVATION DRAWING DETAILS |
| | PER FBC ACC: |
| | A) GRAB BAR HEIGHTS FROM THE FINISHED FLOOR ARE SHOWN |
| | TO THE CENTERLINES OF THE GRAB BARS INSTEAD OF THE TOPS |
| | OF THE GRIPPING SURFACES- SECTION 609.4 FBC ACC. |
| | B) LAVATORY KNEE CLEARANCE DIMENSION TO THE UNDERSIDE |
| | OF THE FIXTURE NOT SHOWN- SECTION 306.3.3. |
| | WHERE KNEE CLEARANCE IS REQUIRED UNDER AN ELEMENT AS |
| | PART OF A CLEAR FLOOR SPACE, THE KNEE CLEARANCE SHALL |
| | BE 11 INCHES DEEP MINIMUM AT 9 INCHES ABOVE THE FINISH |
| | FLOOR OR GROUND, AND 8 INCHES DEEP MINIMUM AT 27 INCHES |
| | ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 4) A030: SITE SPECIFIC ACCESSIBILITY DETAILS FOR THE |
| | STAFF SINK NOT SHOWN INCLUDING- |
| | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS- SECTIONS |
| | 606.2, 305 & 306. |
| | B) MOUNTING HEIGHT OF THE SINK RIM OR COUNTER FROM THE |
| | FINISHED FLOOR- 606.3. |
| | C) REACH RANGE TO FAUCET AND COUNTER DEPTH- 606.4, 308 |
| | & 309. |
| | |
| | 5) A030: SITE SPECIFIC ACCESSIBILITY DETAILS FOR THE |
| | DRINKING FOUNTAINS NOT SHOWN INCLUDING- |
| | A) THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR |
| | FORWARD WHEELCHAIR APPROACH- SECTION 602.2. FBC ACC. |
| | B) KNEE AND TOE CLEARANCES- SECTION 306. |
| | C) SPOUT HEIGHT AND SPOUT LOCATION- SECTION 602.4 AND |
| | 602.5. |
| | |
| | 6) A030: SITE SPECIFIC ACCESSIBILITY DETAILS FOR THE |
| | BOTTLE FILLER NOT SHOWN INCLUDING- |
| | A) THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR |
| | FORWARD WHEELCHAIR APPROACH- SECTION 602.2. FBC ACC. |
| | C) REACH RANGES TO FILLER- SECTIONS 308 & 309. |
| | |
| | 7) P-510 RISERS: |
| | A) SHOW THE TRAP PRIMER CONNECTION- SECTION 1002.4.1 |
| | FBC P |
| | B) PLEASE NOTE THAT TEMPERED WATER IS REQUIRED AT THE |
| | LAVATORY PER SECTION 416.5 SHOW THE LOCATION OF THE |
| | TEMPERATURE LIMITING DEVICE- SECTION 607.1.2. |
| | C) SHOW THE LOCATIONS OF REQUIRED WATER HAMMER |
| | ARRESTORS TO THE FIXTURES- SEE SECTION 604.9. |
| | D) SHOW THE REQUIRED BACKFLOW PREVENTER AT THE REMOTE |
| | CHILLER- SECTION 608.3 |
| | E) VENT CONTINIUATION TO THE EXTERIOR OF THE BUILDING |
| | NOT SHOWN- SECTION 904.1. |
| | |
| | 8) 5-520: PLEASE ADD THE REQUIRED DEVICES LISTED ABOVE |
| | IN COMMENT 7 TO THE PLUMBING FIXTURE SCHEDULE- SECTION |
| | 107.2.1 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | CCOLE@WPB |
| | |