| 2021-01-25 12:52:04 | 01/25/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS |
| | |
| | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| | |
| | 1. ON SHEET P-01: |
| | A. UNDER THE PLUMBING NOTE, FBC PLUMBING 2010 REFERS TO |
| | THE CHANGE TO THE CURRENT YEAR PER THE WPB AMENDMENTS |
| | TO THE FBC SEC. 101.4 REFERENCED CODES. |
| | |
| | B. PLEASE PROVIDE A NOTE THE HOT WATER LINE, NOT IN |
| | CONDITION SPACE, SHALL BE INSULATED WITH AN R-3 FACTOR |
| | PER THE 2017 F FBC RE 403.5.3. |
| | |
| | C. THERE APPEAR TO BE TWO ISOMETRIC DRAWINGS. THIS |
| | REVIEW WILL BE DONE ON P-01, SO PLEASE REMOVE THE P-01 |
| | ISOMETRIC PER THE WPB AMENDMENTS TO THE FBC SEC. |
| | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | 2. ON SHEET P-02; |
| | A. THE CLEANOUT SHALL BE NO MORE THAN 10? FROM THE |
| | BUILDING ENTRANCE. PLEASE PROVIDE A DISTANCE ON THE |
| | FLAT DRAWING TO COMPLY WITH 201 FBC SEC. R P3005.2.3 |
| | BUILDING DRAIN AND BUILDING SEWER JUNCTION. |
| | |
| | B. ON THE WASHING MACHINE STACK, PLEASE SHOW THE P-TRAP |
| | ABOVE GROUND AND A VENT ( A.A.V. OR VTR) PER THE WPB |
| | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. |
| | |
| | C. THE WATER CLOSET IN THE POWDER ROOM IS NOT VENTED. |
| | PLEASE VENT WITH LAV PER THE 2017 FBC SEC R 3101.2.1 |
| | VENTING REQUIRED. |
| | |
| | D. THE KITCHEN IS SHOWN AS AN UNDER THE GROUND P-TRAP |
| | AND NOT VENTED CORRECTLY; PLEASE CHANGE TO ABOVE GROUND |
| | AND VENT TO COMPLY WITH THE 2017 FBC SEC R 3101.2.1 |
| | VENTING REQUIRED. |
| | |
| | C. THE PATIO SIN IS ON A WENT VENT BATHROOM GROUP. |
| | PLEASE MOVE DOWNSTREAM PER THE 2017 FBC SECTION R3108.1 |
| | HORIZONTAL WET VENT PERMITTED. |
| | |
| | 3. PLEASE COMPLY WITH SIGNATURE REVIEW COMMENTS PER THE |
| | WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. |
| | |
| | 4. ON SHEET P-04, THE DRAIN LINE ON THE TANKLESS WATER |
| | HEATER MAY BE A CONDENSATE LINE AND, IF SO, WILL BE |
| | REQUIRED TO BE 1' AWAY FROM THE STRUCTURE PER THE 2017 |
| | FBC SEC. R318.5. |
| | |
| | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |