| Plan Review Notes For Permit 20070175 |
| Permit Number |
20070175 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-07-16 08:53:27 | ROOFING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT | | | APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED | | | ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR | | | ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE | | | THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-60) - | | | SEE NOTE NUMBER 9 OR GENERAL LIMITATION NUMBER 7 ON THE | | | PRODUCT APPROVAL. SIGNED AND SEALED DRAWINGS OR | | | DOCUMENTS WILL NEED TO BE DIGITALLY SIGNED AND SEALED | | | TO BE USED IN ELECTRONIC PLAN REVIEW. SHOW THE WIND | | | DESIGN DATA USED PER 2017 FBC AND ASCE 7-10 - WIND | | | SPEED - EXPOSURE - RISK CATEGORY - ETC. | | | 2) YOU HAVE 2 PRODUCT APPROVALS FOR THE FLAT DECK - | | | PLEASE REMOVE 1 OF THEM FROM THE FOLDERS (FL 2533-R21) | | | AND (MIAMI DADE 20-0131.01) OR STATE ON THE PRODUCT | | | APPROVAL WHAT EACH ONE IS FOR. |
|