| Plan Review Notes For Permit 20061452 |
| Permit Number |
20061452 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-07-10 15:22:22 | RESIDENTIAL (R3) REVISION BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK | | | SHALL COMPLY WITH THE MATERIALS AND METHODS | | | REQUIREMENTS IN THE FLORIDA BUILDING CODE. | | | | | | 1- PROVIDE COMPLETE SINGLE HUNG PRODUCT APPROVAL. ONLY | | | THE FLORIDA PRODUCT APPROVAL FL30344-R1 COVER PAGE WAS | | | SUBMITTED. NEED TO PROVIDE COMPLETE PRODUCT APPROVAL | | | INCLUDING THE INSTALLATION DRAWINGS THAT CORRESPOND TO | | | FLORIDA PRODUCT APPROVAL SUBMITTED. FAC 61G20-3.001. | | | | | | 2- -CLEARLY SPECIFY TYPE AND SIZE OF EXISTING WINDOWS | | | AND TYPE AND SIZE OF PROPOSED WINDOWS TO VERIFY | | | COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. 702.5 | | | FBC-EXISTING BUILDING. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|