Plan Review Notes
Plan Review Notes For Permit 20061444
Permit Number 20061444
Review Stop B
Sequence Number 1
Notes
Date Text
2020-07-07 08:18:57APPROVED WITH EXCEPTIONS. BUILDING PROVISO.
  
 1) A SEPARATE PERMIT APPLICATION, PLANS AND REVIEW IS
 REQUIRED FOR THE FABRIC AND ITS ATTACHMENT TO THE THE
 METAL FRAMES. FBC 107
  
 2) WORKING CLEARANCES SHALL BE MAINTAINED AROUND THE
 EQUIPMENT THAT IS BEING SCREENED. FBCM 303.12 & FBC 107
  
 WELDING COMMENTS
  
 AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S.
 SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING:
 BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO
 BE USED.
  
 AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE
 W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO
 VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS
 IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT.
  
  