| Plan Review Notes For Permit 20060618 |
| Permit Number |
20060618 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-06-17 08:39:13 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE STAIR PLAN VIEW #5 OF THE 5TH LEVEL ON SHEET | | | SD-01 DOES NOT APPEAR TO SHOW COMPLIANCE WITH FBC | | | ACCESSIBILITY SECTION 505.10.2 FOR THE HANDRAIL | | | EXTENSION AT THE TOP OF THE STAIRS. THE HANDRAIL IS | | | REQUIRED TO EXTEND HORIZONTALLY FOR 12 INCHES BEGINNING | | | DIRECTLY ABOVE THE FIRST RISER NOSING. THE DRAWING | | | APPEARS TO SHOW THE HANDRAIL MAKING A 90 DEGREE TURN | | | AND EXTENDING FOR 12" PERPENDICULAR TO THE STAIRS. |
|