| Date |
Text |
| 2020-08-13 12:19:42 | 2ND REVIEW FBC-2017 PLUMBING |
| | PERMIT- 20060456 |
| | 8/13/2020 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIE |
| | COMMENTS FROM THE 1ST REVIEW LISTED BELOW WERE NOT |
| | ADDRESSED AND STILL EXIST WITH THE EXCEPTIONS OF |
| | COMMENTS # 6,A,E,G & H. NEW COMMENTS #8, 9 & 10 WERE |
| | ADDED. PLEASE NOTE THAT THE REQUESTED RESPONSE |
| | NARRATIVE TO THESE COMMENTS WAS NOT PROVIDED |
| | |
| | 1) SHEET P1: THE SINK FIXTURE DRAIN MUST CONNECT TO THE |
| | 3" BUILDING DRAIN DOWNSTREAM OF THE WC AND LAVATORY PER |
| | SECTIONS 912.1 AND 912.2.1 FBC P. |
| | |
| | 2) P1: PROVIDE A WATER RISER DRAWING SHOWING PIPE |
| | SIZES, LOCATIONS OF SHUTOFF VALVES, WATER HAMMER |
| | ARRESTORS, MIXING VALVES ETC.- SECTION 107.3.5.1.3 WPB |
| | AMENDMENTS TO THE FBC. |
| | |
| | 3) P1: PROVIDE A PLUMBING FIXTURE AND DEVICE SCHEDULE- |
| | SECTION 107.2.1 WPB & SECTION 405.9 FBC P. |
| | |
| | 4) P1: PROVIDE PLUMBING FIXTURE CALCULATIONS FOR THE |
| | PROPOSED ALTERATIONS PER TABLE 403.3 FBC P. PROVIDE A |
| | SCHEDULE INDICATING THE REQUIRED AND PROVIDED PLUMBING |
| | FIXTURES. PLEASE NOTE THAT THE PLAN DOES NOT INDICATE |
| | DRINKING FOUNTAINS, OR A SERVICE SINK ARE EITHER |
| | EXISTING OR PROPOSED. REFER TO SECTION 211.1- 211.3 FBC |
| | ACC FOR ACCESSIBLE DRINKING FOUNTAIN REQUIREMENTS. |
| | REVISE THE PLANS TO SHOW COMPLIANCE. |
| | |
| | 5) P1: INDICATE HOW TEMPERED WATER WILL BE PROVIDED TO |
| | THE LAVATORY- SECTION 416.5 FBC P. |
| | |
| | 6) A4: ACCESSIBILITY CORRECTIONS FOR THE 1ST FLOOR |
| | RESTROOM - FBC ACC: |
| | B) HEIGHT TO THE TOP OF THE WATER CLOSET SEAT FROM THE |
| | FINISHED FLOOR INCORRECTLY INDICATED AT 20"- SECTION |
| | 604.4 |
| | C) THE SIDE GRAB BAR AT THE WATER CLOSET SHALL EXTEND |
| | MINIMUM 54" FROM THE REAR WALL- FIGURE 604.5.1. |
| | D) REAR GRAB BEHIND WATER CLOSET NOT CENTERED |
| | CORRECTLY- FIGURE 604.5.2. |
| | F) FLUSH CONTROL SHOWN ON THE WRONG SIDE OF THE WATER |
| | CLOSET- SECTION 604.6 |
| | I) KNEE AND TOE CLEARANCES FOR THE LAVATORY NOT SHOWN- |
| | SECTIONS 305 & 306. |
| | |
| | 7) A2, A3, & A4: NO ACCESSIBILITY DETAILS HAVE BEEN |
| | PROVIDED FOR THE ALTERED SECOND FLOOR BATHROOM. THE |
| | CONFIGURATION OF THE ROOM INDICATES NON-COMPLIANCE. |
| | PLEASE PROVIDE ENLARGED DRAWINGS AND DETAILS TO SHOW |
| | COMPLIANCE WITH THE FBC ACC: |
| | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | WATER CLOSET- SECTION 604.3. |
| | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | LAVATORY- SECTION 606.2. |
| | C) DIAGRAMS AND DIMENSIONS FOR THE NEW SHOWER PER |
| | SECTION 608.2.1 AND FIGURE 608.2.1. THE SHOWER |
| | COMPARTMENT SHALL BE 36 INCHES BY 36 INCHES CLEAR |
| | INSIDE DIMENSIONS MEASURED AT THE CENTER POINTS OF |
| | OPPOSING SIDES AND SHALL HAVE A 36-INCH WIDE MINIMUM |
| | ENTRY ON THE FACE OF THE SHOWER COMPARTMENT. CLEARANCE |
| | OF 36 INCHES WIDE MINIMUM BY 48 INCHES LONG MINIMUM |
| | MEASURED FROM THE CONTROL WALL SHALL BE PROVIDED. |
| | D) BATHROOM ENTRY DOOR WIDTH, DOOR SWING, AND |
| | WHEELCHAIR APPROACHES- SECTION 604.8.1.2 & 604.8.1.3. |
| | E) TURNING SPACE DIAMETERS SECTION 304.3. |
| | F) CENTERLINE OF THE WATER CLOSET FROM THE SIDE WALL- |
| | SECTION 604.2. |
| | G) HEIGHT OF THE WATER CLOSET SEAT FROM THE FINISHED |
| | FLOOR- SECTION 604.4. |
| | H) HEIGHT OF THE FRONT RIM OF THE LAVATORY FROM THE |
| | FINISHED FLOOR- SECTION 606.3 |
| | I) KNEE AND TOE CLEARANCES FOR THE LAVATORY- SECTION |
| | 306. |
| | J) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB |
| | BARS- SECTION 604.5 & 609.4. |
| | K) LOCATION OF THE WATER CLOSET FLUSH CONTROL- SECTION |
| | 604.6. |
| | L) LOCATION, CLEARANCE, AND MOUNTING HEIGHT FOR THE |
| | TOILET PAPER DISPENSER- SECTION 604.7. |
| | M) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE |
| | BOTTOM OF THE REFLECTIVE SURFACE- SECTION 603.3 |
| | N) NEW SHOWER GRAB BAR AND SHOWER CONTROL LOCATIONS AND |
| | CLEARANCES PER SECTIONS AND FIGURES 608.3.1 & 608.5.1. |
| | O) LOCATION AND DETAILS FOR INSTALLATION OF THE |
| | REQUIRED SEAT IN THE SHOWER- SECTION 608.4 & 610.3. |
| | |
| | 8) NEW COMMENT. SHEET A3, A4., P1: PROVIDE DIMENSIONED |
| | FRONT AND SIDE ELEVATION DRAWINGS OF THE NEW BREAK ROOM |
| | SINK. THE SINK SHALL BE INSTALLED WITH THE FRONT OF THE |
| | HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES FROM THE |
| | FINISHED FLOOR- SECTION 606.3 FBC ACC. THE DEPTH OF THE |
| | COUNTERTOP SHALL BE INCOMPLIANCE WITH SECTION 308.3.2 |
| | FOR ALLOWABLE REACH RANGES TO THE FAUCET CONTROLS. |
| | |
| | 9) NEW COMMENT, SHEET P1: PLEASE LABEL THE WATER HEATER |
| | IN THE MECH RM AS EITHER NEW OR EXISTING, IF THE UNIT |
| | IS BEING REPLACED, PLEASE PROVIDE A PLUMBING PIPING |
| | DETAIL AND AN EQUIPMENT SCHEDULE ON THE PLAN, AND |
| | SUBMIT A PRODUCT SPEC SHEET- SECTIONS 502.1 AND 607.1. |
| | |
| | 10) NEW COMMENT: PROVIDE WALL AND FLOOR FINISH MATERIAL |
| | SCHEDULES FOR THE BATHROOMS- SEE SECTION 310.3 FBC P |
| | AND SECTION 1210.2.2 FBC B. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | CCOLE@WPB |
| | |