2020-07-17 09:06:551ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20060205
  
 CODES IN EFFECT:
  
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE ENERGY CALCULATIONS AND MANUAL J
 CALCULATIONS FOR THE NEW ADDITION. FBC EC 101.5.1.1.2
  
 2) PROVIDE CALCULATIONS ON SIZING OF THE MECHANICAL
 SYSTEM. FBC EC R403.7
  
 3) PROVIDE MECHANICAL DRAWINGS FOR THIS PROJECT. FBC FS
 107.2.1
  
 4) PROVIDE SPECIFICATIONS FOR THE MECHANICAL SYSTEM
 USED IN THIS PROJECT, ALSO PROVIDE SPECIFICATIONS FOR
 THE BATH EXHAUST FAN. FBC FS 107.2.1
  
 5) SHOW HOW THE CONDENSATION WILL BE DISPOSED FROM NEW
 UNIT. FBC RES M1411.3
  
 6) PROVIDE DETAIL OF THE ANCHORING OF THE CONDENSING
 UNIT. FBC RES M1307.2
  
 7) SHOW THE RETURN AIR PATH BACK TO THE AHU, IF THE
 DOOR AT THE AHU IS A LOUVER DOOR PROVIDE INFO ON THE
 DOOR. FBC RES M1602.3
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  