| Date |
Text |
| 2020-06-22 12:21:08 | PLAN |
| | REVIEW COMMENTS |
| | 5TH REVIEW: FBC SIXTH EDITION (2017) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING - PREVIOUS COMMENTS WERE NOT |
| | ADDRESSED |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) (REPEAT COMMENT. THE WINDLOAD CALCULATIONS ARE NOT |
| | DIGITALLY SIGNED.) SUBMIT REQUIRED COMPONENT AND |
| | CLADDING DESIGN PRESSURES FOR THE OPENINGS THAT HAVE |
| | BEEN PREPARED BY A FLORIDA LICENSED ENGINEER. THE |
| | DOCUMENTS ARE REQUIRED TO BE DIGITALLY SIGNED BY THE |
| | ENGINEER IF SUBMITTED ELECTRONICALLY AND THE ENGINEER'S |
| | ORIGINAL HANDWRITTEN SIGNATURE IF PAPER DOCUMENTS ARE |
| | SUBMITTED. FS 471 & FAC 61G15 THESE DOCUMENTS ARE |
| | SUBMITTED ELECTRONICALLY, THEREFORE, THE ENGINEER IS |
| | REQUIRED TO DIGITALLY SIGN THE DESIGN PRESSURE CHART. |
| | |
| | 2) THE DESIGN PRESSURE CAPACITY FOR THE MULLION THAT IS |
| | SPECIFIED ON SHEET 5 OF 25 OF THE PRODUCT APPROVAL IS |
| | 35.3 PSF. THIS IS TOO LOW. PLEASE REVISE. FBC 107 |
| | ( NEW NOTE: SEE PAGES 28 AND 29 OF THE MULLION PRODUCT |
| | APPROVAL. THIS IS RECTANGULAR LOADING. THE MULL LENGTH |
| | IS 62 INCHES. THE OPENING WIDTH IS 36 INCHES + 36 |
| | INCHES + THE MULL WIDTH = 72 + MULL WIDTH. IF THE EXACT |
| | SIZES ARE NOT LISTED IN THE CHART USE THE NEXT HIGHEST. |
| | THE MULL THAT IS USED IS REQUIRED TO HAVE DESIGN |
| | PRESSURES THAT ARE HIGHER THAN THE PRESSURES REQUIRED |
| | FOR THE OPENING. IF THE REQUIRED OPENING PRESSURES ARE |
| | +65.9 PSF, -120.8 PSF THEN THE MULLION DESIGN PRESSURES |
| | ARE REQUIRED TO BE GREATER THAN THAT.) |
| | |