| Date |
Text |
| 2020-06-24 17:09:22 | 1ST REVIEW FBC-2017 PLUMBING |
| | PERMIT 20050856 |
| | 6/24/2020 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) REFER TO TABLE 403.3 FBC P AND PROVIDE A SCHEDULE ON |
| | THE PLAN INDICATING THE REQUIRED AND PROVIDED PLUMBING |
| | FIXTURES FOR THE BUSINESS OCCUPANCY. THE DEMOLISHED |
| | WATER CLOSET AND LAV SINK MAY HAVE TO BE REPLACED |
| | DEPENDING ON THE OCCUPANT LOAD OF THE FLOOR AND THE |
| | NUMBER OF COMMUNAL FIXTURES AVAILABLE FOR ALL |
| | OCCUPANTS- SECTION 107.2.1 WPB. |
| | |
| | 2) THE NEW TENANT SINK, AND THE REPLACED SINK IN THE |
| | ADJACENT OCCUPANCY SHALL BE INSTALLED IN ACCORDANCE |
| | WITH ACCESSIBILITY REQUIREMENTS UNDER SECTION 606.1- |
| | 606.5 FBC ACC. PROVIDE DETAILS AND SPECIFICATIONS TO |
| | INDICATE COMPLIANCE. |
| | |
| | 3) CONNECTING THE NEW SINK DRAIN TO THE EXISTING |
| | SANITARY MAY REQUIRE THE FLOOR SLAB TO BE X-RAYED IN |
| | ORDER TO LOCATE POST STRESSED TENDONS OR STEEL |
| | REINFORCEMENTS. PLEASE PROVIDE ADDITIONAL INFORMATION |
| | ON THE PLAN, |
| | |
| | 4) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB |
| | WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE |
| | AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED |
| | FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION |
| | 714.4.1.2 FBC-B. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |