Plan Review Notes
Plan Review Notes For Permit 20050856
Permit Number 20050856
Review Stop B
Sequence Number 1
Notes
Date Text
2020-06-01 10:31:192017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050856
 ADD: 525 OKEECHOBEE BLVD. SUITE: 860
 CONT: HOLT-LEE
 TEL:954-725-4881
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MONDAY JUNE 01/2020
 ACTION: DENIED
  
 1) SHEET A1.2 L. S. SHEET ROOM 873 IS SHOWN AS THE
 BREAKROOM. SHEET A1.3 SHOWS THE DETAILS OF THE BREAK
 ROOM WITH A STONE COUNTER TOP AT 42 INCHES ABOVE FINISH
 FLOOR.
 THE PLAN DOES NOT SHOW SEATING AT THE COUNTER BUT CAN
 ONLY BE ASSUMED THAT THE COUNTER/ HI-TOP WILL BE USED
 FOR EITHER DRINKING OR EATING FOODS SINCE THIS IS A
 BREAK ROOM.
 1A) 902.1 .DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3 OF THE 2017
 FBC-ACCESSIBILITY CODE. ADVISORY 902.1 GENERAL. DINING
 SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, TABLES,
 LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK SURFACES
 INCLUDE WRITING SURFACES, STUDY CARRELS, STUDENT
 LABORATORY STATIONS, BABY CHANGING AND OTHER TABLES OR
 FIXTURES FOR PERSONAL GROOMING, COUPON COUNTERS, AND
 WHERE COVERED BY THE ADA SCOPING PROVISIONS, EMPLOYEE
 WORK STATIONS.
  
 1A)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 1A)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
  
 1B) THE LIFE SAFETY SHEET DOES NOT SHOW COMPLIANCE WITH
 THE 2017 FBC-ACCESSIBILITY CODE NOR SHEET A1.3 WITH
 226.1 2017 ACCESSIBILITY CODE. WHERE DINING SURFACES
 ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT
 LEAST 5 PERCENT OF THE SEATING SPACES AND STANDING
 SPACES AT THE DINING SURFACES SHALL COMPLY WITH 902.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE
 TO CONTACT ME, MY CELL NUMBER IS 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  