2020-07-22 11:52:032017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050672
 ADD: 1320 ALPHA ST.
 CONT: GEN-X-CONSTRUCTION
 TEL: 561-963-4490
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. JULY 22ND/2020
 ACTION: DENIED
  
 1) SEMI-COMPLIED. SHEET A8.02 DOES SHOW THE SLAB REPAIR
 AND SHEET A8.01 SHOWS THE ONE HOUR FIRE RATING FOR
 BETWEEN UNITS WITH FIRE X DRYWALL BUT THERE IS NO
 MENTION IN THIS DETAIL HOW COMPLIANCE IS TO BE MET IN
 THE SHOWER WHERE YOU WILL ALSO NEED TO SHOW COMPLIANCE
 WITH SECTION: 2509.2 BASE FOR TILE IN THE 2017 FBC-B.
 MATERIALS USED AS A BASE FOR WALL TILE IN TUB AND
 SHOWER AREAS AND WALLS AND CEILING PANELS IN SHOWER
 AREAS SHALL BE OF MATERIALS LISTED IN TABLE 2509.2 AND
 INSTALLED IN ACCORDANCE WITH MANUFACTURER?S
 RECOMMENDATIONS. WATER RESISTANT GYPSUM BACKING BOARD
 SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET
 COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH
 GA-216 OR ASTM C840 AND THE MANUFACTURER'S
 RECOMMENDATIONS.
  
 2) SEMI- COMPLIED SEE COMMENT # 1. PLEASE PROVIDE IN
 THE FLOOR PLAN, THE R2 UNITS THAT ARE BACK TO BACK AND
 HAVE REPLACEMENT PLUMBING IN THESE WALLS. SHOW HOW
 CONFORMANCE WITH THE 1 HOUR FIRE SEPARATION (FIRE
 PARTITIONS) REQUIRED BY SECTION708.1 AND 420 FBC-B AND
 IN CONFORMANCE WITH THE FIRE RESISTANCE RATING OF
 708.3.
 .
 3) COMPLIED. PLUMBING THAT IS WITHIN THE 1 HOUR TENANT
 SEPARATION WALL AND EXTENDS THROUGH THE WALL MEMBRANE
 WILL NEED TO PROVIDE COMPLIANCE WITH 714.3.2 COMPLYING
 WITH 714.3.1.2 THROUGH- PENETRATION FIRESTOP SYSTEM.
  
 4) COMPLIED. IT IS UNKNOWN IF THIS IS A MULTIPLE STORY
 APARTMENT COMPLEX, THIS INFORMATION WAS NOT GIVEN. IF
 SO COMPLIANCE WITH 714.4 HORIZONTAL ASSEMBLIES AND
 714.4.1 THROUGH PENETRATIONS AND 714.4.1.2. HORIZONTAL
 THROUGH-PENETRATIONS FIRESTOP ASSEMBLIES WILL NEED TO
 SHOW COMPLIANCE.
  
 5) COMPLIED. THE BUILDING PLANS WILL NEED TO COMPLY
 WITH THE, 107.2.1.3. QUALITY OF PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A 1/8TH INCH SCALE ON SUBSTANTIAL
 PAPER OR OTHER ACCEPTABLE MEDIUM. THE BUILDING OFFICIAL
 MAY ESTABLISH THROUGH DEPARTMENT POLICY OTHER STANDARDS
 FOR THE PLANS AND SPECIFICATIONS IN ORDER TO PROVIDE
 CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY
 MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE,
 CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORD
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES.
  
 6) 2ND REQUEST. THE SUBMITTED PLANS BY ARCHITECT HAROLD
 TUTTLE IT WOULD APPEAR TO BE PAPER PLANS AND WOULD NEED
 TO BE UPLOADED WITH DIGITAL SIGNATURES. ARCHITECTS:
 FLORIDA ADMINISTRATIVE CODE 61G1-16.005. PROCEDURES FOR
 DIGITALLY SIGNING AND SEALING AND FOR ELECTRONICALLY
 TRANSMITTING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS.
  
 1ST ROUND OF COMMENTS. CERTIFICATION BY CONTRACTOR.
 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE
 EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H)
 ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C)
 (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT
 WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE
 CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DRAWN THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN. FOR EACH TRADE THE CONTRACTOR
 RESPONSIBLE FOR THE DESIGN UNDER THE TRADE LICENSED IN
 MUST PRINT THEIR NAME, SIGN THEIR NAME AND LICENSE
 NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY ONE
 INDUVIAL, THEY WOULD HAVE TO BE LICENSED AS A BUILDING,
 ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT ALL THESE
 TRADES UNDER ONE SHEET.
  
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE
 TO CONTACT ME, MY CELL NUMBER IS 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved