2020-08-25 10:58:382017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050017
 ADD: 20050017
 CONT: 2218 S DIXIE HWY.
 TEL: 561-324-3163
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. AUGUST 25TH/ 2020
 ACTION: DENIED
  
 1-2) COMPLIED.
  
 3) SEMI-COMPLIED. PLEASE SEE SHEET E-1 THE ELECTRICAL
 FLOOR PLAN STILL SHOWS AN ACTIVE 240 VOLT OUTLET AT THE
 STOVE, WITH CIRCUITS D24 & 26 STILL ON THE PLANS.
 1ST ROUND COMMENTS. SHEET A-2, THE LIFE SAFETY SHEET
 NOR THE MECHANICAL SHEET INDICATE A HOOD SYSTEM OVER
 THE STOVE WITHIN THE KITCHEN. NONE OF THESE PLANS
 INDICATE IF THE KITCHEN IS OPERATIONAL, OR IF A SALES
 DISPLAY? ADDITIONAL INFORMATION IS REQUIRED.
 DOES THE KITCHEN NEED TO SHOW COMPLIANCE WITH THE 2017
 FBC-B SECTION 904.2.2?
  
 4-6) COMPLIED.
  
 7 SEMI-COMPLIED. )SHEET A-5 FIGURES 604.5.1 & FIGURE
 604.5.2 BOTH SHOW THE REQUIRED LENGTH OF GRAB BARS BUT
 NOT THE REQUIRED HEIGTH.
 GRAB BARS/ RESTROOMS> 2017 FBC-ACCESSIBILITY CODE
 SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE
 INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM
 AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED
 TO THE TOP OF THE GRIPPING SURFACE. NOT CENTERLINE.
  
 1ST ROUND OF COMMENTS. THE FLOOR PLAN AND LIFE SAFETY
 PLAN SHOW NEW RESTROOMS BUT THERE ARE NO DETAIL AS TO
 FLOOR PLAN OR ELEVATIONS SHOWING COMPLIANCE WITH
 CHAPTER 6 OF THE ACCESSIBILITY CODE.
  
 8) COMPLIED.
  
 9) NEW COMMENT. THIS COMMENT IS A RESULT OF THE
 BUILDING OFFICIAL INTERPRETATION. IN RESTROOMS EPOXY
 PAINT IS NO LONGER CONSIDERED A SMOOTH HARD,
 NON-ABSORBENT SURFACE.
 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. WALLS &
 PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND
 WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT
 SURFACE TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE
 FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIAL
 USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT
 ADVERSELY AFFECTED BY MOISTURE.
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE
 TO CONTACT ME, MY CELL NUMBER IS 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  