| Date |
Text |
| 2020-08-25 10:58:38 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20050017 |
| | ADD: 20050017 |
| | CONT: 2218 S DIXIE HWY. |
| | TEL: 561-324-3163 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: TUES. AUGUST 25TH/ 2020 |
| | ACTION: DENIED |
| | |
| | 1-2) COMPLIED. |
| | |
| | 3) SEMI-COMPLIED. PLEASE SEE SHEET E-1 THE ELECTRICAL |
| | FLOOR PLAN STILL SHOWS AN ACTIVE 240 VOLT OUTLET AT THE |
| | STOVE, WITH CIRCUITS D24 & 26 STILL ON THE PLANS. |
| | 1ST ROUND COMMENTS. SHEET A-2, THE LIFE SAFETY SHEET |
| | NOR THE MECHANICAL SHEET INDICATE A HOOD SYSTEM OVER |
| | THE STOVE WITHIN THE KITCHEN. NONE OF THESE PLANS |
| | INDICATE IF THE KITCHEN IS OPERATIONAL, OR IF A SALES |
| | DISPLAY? ADDITIONAL INFORMATION IS REQUIRED. |
| | DOES THE KITCHEN NEED TO SHOW COMPLIANCE WITH THE 2017 |
| | FBC-B SECTION 904.2.2? |
| | |
| | 4-6) COMPLIED. |
| | |
| | 7 SEMI-COMPLIED. )SHEET A-5 FIGURES 604.5.1 & FIGURE |
| | 604.5.2 BOTH SHOW THE REQUIRED LENGTH OF GRAB BARS BUT |
| | NOT THE REQUIRED HEIGTH. |
| | GRAB BARS/ RESTROOMS> 2017 FBC-ACCESSIBILITY CODE |
| | SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE |
| | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM |
| | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED |
| | TO THE TOP OF THE GRIPPING SURFACE. NOT CENTERLINE. |
| | |
| | 1ST ROUND OF COMMENTS. THE FLOOR PLAN AND LIFE SAFETY |
| | PLAN SHOW NEW RESTROOMS BUT THERE ARE NO DETAIL AS TO |
| | FLOOR PLAN OR ELEVATIONS SHOWING COMPLIANCE WITH |
| | CHAPTER 6 OF THE ACCESSIBILITY CODE. |
| | |
| | 8) COMPLIED. |
| | |
| | 9) NEW COMMENT. THIS COMMENT IS A RESULT OF THE |
| | BUILDING OFFICIAL INTERPRETATION. IN RESTROOMS EPOXY |
| | PAINT IS NO LONGER CONSIDERED A SMOOTH HARD, |
| | NON-ABSORBENT SURFACE. |
| | 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. WALLS & |
| | PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND |
| | WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT |
| | SURFACE TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE |
| | FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIAL |
| | USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT |
| | ADVERSELY AFFECTED BY MOISTURE. |
| | |
| | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE |
| | TO CONTACT ME, MY CELL NUMBER IS 561-718-9724. |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |