| 2020-05-13 10:20:10 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20041048 |
| | ADD: 6411 PARKER |
| | CONT: TBD/ TO BE DETERMINED |
| | TEL: 305-725-5401 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. MAY 13TH/ 2020 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A-1 INDICATES THE CODES THIS STRUCTURE WAS |
| | DESIGNED TO IS THE 2017 FBC-COMMERCIAL (BUILDING) AND |
| | THE 2017 FBC-RESIDENTIAL CODE. |
| | PLEASE NOTE THE RESIDENTIAL CODE IS TO BE USED STRICTLY |
| | FOR ONE AND TWO FAMILY DWELLING UNITS. PLEASE UPDATE |
| | THE PLANS. |
| | |
| | 2) SHEET A-5 THE ROOF FRAMING PLAN SHOWS THE ROOF |
| | DRAINAGE BROKEN INTO 2 SECTIONS WITH ROOF DRAINS. NOTES |
| | TO THE RIGHT OF THE ROOF FRAMING PLAN INDICATES THE |
| | ROOF THICKNESS TO BE FROM 13 ? INCHES TO 6 INCHES AT |
| | EACH OF THE ROOF DRAINS. THAT IS A DIFFERENCE OF 7 ? |
| | INCHES IN HEIGHT. THE PLAN DOES NOT SHOW A SECONDARY |
| | ROOF DRAINAGE SYSTEM NOR A SECONDARY (EMERGENCY |
| | OVERFLOW) DRAINS OR SCUPPERS IN ACCORDANCE WITH SECTION |
| | 1503.4.1 OF THE 2017 FBC-B. ALSO REVIEW 1503.4.2.1. |
| | OVERFLOW SCUPPERS. |
| | |
| | 3A) SHEET A-4 SHOWS THE ROOFING PRODUCT TO BE A SINGLE |
| | PLY 60 MIL. TPO ROOFING MEMBRANE (20 YEAR). THIS REVIEW |
| | NO ROOFING PRODUCT APPROVAL WAS SUBMITTED. SINCE THERE |
| | IS NO CONTRACTOR SIGNED ONTO THIS PERMIT THE DESIGNER |
| | OF RECORD MAY WANT TO CONSIDER THE PRODUCT APPROVAL TO |
| | BE A DEFERRED SUBMITTAL. |
| | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS |
| | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE |
| | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE |
| | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO |
| | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. |
| | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR |
| | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED |
| | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST |
| | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS |
| | FOR REVIEW BY THE BUILDING OFFICIAL. |
| | |
| | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| | THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL |
| | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED |
| | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING |
| | OFFICIAL. |
| | |
| | 3B) COMPONENTS & CLADDING. 2017 FBC-B 1609.6.4.4.1 |
| | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY |
| | AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 |
| | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR |
| | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES, |
| | |
| | 3C) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE |
| | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 3D) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY |
| | ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES |
| | FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL |
| | LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF |
| | ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR |
| | THE BASE SHEET AS CALCULATED IN COMPLIANCE WITH ROOFING |
| | APPLICATION STANDARDS RAS 117. CALCULATION PREPARED, |
| | SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL |
| | ENGINEER OR REGISTERED ARCHITECT. 1609.6.4.4.1 |
| | COMPONENTS & CLADDING. |
| | |
| | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE |
| | TO CONTACT ME, MY CELL NUMBER IS 561-718-9724. |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |