| Date |
Text |
| 2020-10-21 12:47:42 | BUILDING REVIEW PROVISO: |
| | 1-WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS |
| | REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS & |
| | WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN |
| | ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF |
| | INSPECTION. |
| | 2017 FBC-B 2204.1 WELDING |
| | 2017 FBC-B 2204.2 BOLTING. |
| | |
| | 2-PROPOSED SLIDING GLASS DOORS NEED TO COMPLY WITH SEC. |
| | 1010.1.4.3 FBC-BUILDING: |
| | SPECIAL PURPOSE HORIZONTAL SLIDING, ACCORDION OR |
| | FOLDING DOORS. |
| | IN OTHER THAN GROUP H OCCUPANCIES, SPECIAL PURPOSE |
| | HORIZONTAL SLIDING, ACCORDION OR FOLDING DOOR |
| | ASSEMBLIES PERMITTED TO BE A COMPONENT OF A MEANS OF |
| | EGRESS IN ACCORDANCE WITH EXCEPTION 6 TO SECTION |
| | 1010.1.2 SHALL COMPLY WITH ALL OF THE FOLLOWING |
| | CRITERIA: |
| | |
| | 1.THE DOORS SHALL BE POWER OPERATED AND SHALL BE |
| | CAPABLE OF BEING OPERATED MANUALLY IN THE EVENT OF |
| | POWER FAILURE. |
| | |
| | 2.THE DOORS SHALL BE OPENABLE BY A SIMPLE METHOD FROM |
| | BOTH SIDES WITHOUT SPECIAL KNOWLEDGE OR EFFORT. |
| | |
| | 3.THE FORCE REQUIRED TO OPERATE THE DOOR SHALL NOT |
| | EXCEED 30 POUNDS (133 N) TO SET THE DOOR IN MOTION AND |
| | 15 POUNDS (67 N) TO CLOSE THE DOOR OR OPEN IT TO THE |
| | MINIMUM REQUIRED WIDTH. |
| | |
| | 4.THE DOOR SHALL BE OPENABLE WITH A FORCE NOT TO EXCEED |
| | 15 POUNDS (67 N) WHEN A FORCE OF 250 POUNDS (1100 N) IS |
| | APPLIED PERPENDICULAR TO THE DOOR ADJACENT TO THE |
| | OPERATING DEVICE. |
| | |
| | 5.THE DOOR ASSEMBLY SHALL COMPLY WITH THE APPLICABLE |
| | FIRE PROTECTION RATING AND, WHERE RATED, SHALL BE |
| | SELF-CLOSING OR AUTOMATIC CLOSING BY SMOKE DETECTION IN |
| | ACCORDANCE WITH SECTION 716.5.9.3, SHALL BE INSTALLED |
| | IN ACCORDANCE WITH NFPA 80 AND SHALL COMPLY WITH |
| | SECTION 716. |
| | |
| | 6.THE DOOR ASSEMBLY SHALL HAVE AN INTEGRATED STANDBY |
| | POWER SUPPLY. |
| | |
| | 7.THE DOOR ASSEMBLY POWER SUPPLY SHALL BE ELECTRICALLY |
| | SUPERVISED. |
| | |
| | 8.THE DOOR SHALL OPEN TO THE MINIMUM REQUIRED WIDTH |
| | WITHIN 10 SECONDS AFTER ACTIVATION OF THE OPERATING |
| | DEVICE. |