| Plan Review Notes For Permit 20040876 |
| Permit Number |
20040876 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2020-08-03 14:28:51 | BUILDING PROVISO 2017 FBC- ACCESSIBILITY CODE: | | | PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS 307.2. | | | OBJECTS WITH LEADING EDGES MORE THAN 27 | | | INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR | | | SHALL NOT PROTRUDE MORE THAN 4 INCHES | | | HORIZONTALLY IN TO THE CIRCULATION PATH. OR ADD WING | | | WALLS TO NOT BUMP INTO THE DRINKING | | | FOUNTAINS. SEE SHEET A-03 AND DETAIL 3/A-08. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|