| 2020-04-21 10:55:34 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20040734 |
| | ADD: 630 SAPODILLA AVE. SUITE: 206 |
| | CONT: FLORIDA ALLIED CONTRACTOR SERVICES |
| | TEL: 239-410-2276 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. APRIL 21/ 2020 |
| | ACTION: DENIED |
| | |
| | 1) SHEET 2 THE PROPOSED FLOOR PLAN INDICATES THE NEW |
| | SHOWER FLOOR DRAIN TO BE MOVED FROM THE PRESENT |
| | LOCATION OF THE TUB. CONTRACTOR WILL NEED TO HAVE THE |
| | FLOOR X-RAYED TO SEE WHERE THE TENDONS IF POST STRESSED |
| | FLOOR OR FOR RE-ENFORCING STEEL BARS IN THE FLOOR SLAB. |
| | PLEASE NOTE ON PLANS BEFORE PERMIT CAN BE ISSUED. |
| | 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 2) SINCE THERE IS GOING TO BE A NEW FLOOR PENETRATION |
| | PLEASE PROVIDE DOCUMENTATION FOR (1) FOR THE OLD FLOOR |
| | OPENING & (2) THE NEW FLOOR OPENING WITH DRAIN LINE, |
| | HOW COMPLIANCE WITH SECTION 714.4.1.2. THROUGH- |
| | PENETRATION FIRESTOP SYSTEMS OF THE 2017 FBC-B ARE TO |
| | BE COMPLIED. |
| | |
| | 3) THE PLANS DO NOT ADDRESS THE TILE BACKING IN THE 2 |
| | NEW SHOWERS. PLEASE PROVIDE THE TYPE OF GYPSUM PRODUCT |
| | WILL BE INSTALLED FOR THE BACKING/ WALL FOR THE TILE. |
| | IN THE 2017 FBC-B SECTION 2509.2 DOES NOT ALLOW THE USE |
| | OF MR BOARD IN SHOWERS. PLEASE IDENTIFY THE BASE FOR |
| | TILE. |
| | |
| | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |