| Date |
Text |
| 2020-05-14 09:59:03 | PLAN REVIEW - BUILDING |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER BUILDING - PX3169 |
| | PLANS EXAMINER 1&2 FAMILY - SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | |
| | NOTICE: THE PROPOSED STRUCTURES ARE LOCATED IN A |
| | SPECIAL FLOOD HAZARD AREA (SFHA) WITH A BASE FLOOR |
| | ELEVATION (BFE) OF 7.0 FEET NAVD. BUILDINGS AND |
| | STRUCTURES LOCATED IN SFHA'S SHALL BE DESIGNED PER FBC |
| | R322. |
| | |
| | R322.1.2STRUCTURAL SYSTEMS. |
| | STRUCTURAL SYSTEMS OF BUILDINGS AND STRUCTURES SHALL BE |
| | DESIGNED, CONNECTED AND ANCHORED TO RESIST FLOTATION, |
| | COLLAPSE OR PERMANENT LATERAL MOVEMENT DUE TO |
| | STRUCTURAL LOADS AND STRESSES FROM FLOODING EQUAL TO |
| | THE DESIGN FLOOD ELEVATION. |
| | |
| | 1. SITE PLAN. IDENTIFY LOCATION OF PROPOSED STRUCTURES. |
| | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED |
| | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY |
| | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF |
| | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, |
| | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES |
| | AND THE PROPOSED FINISHED GRADES, DEPICTING THE |
| | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD |
| | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT |
| | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| | INCLUDED ON A BOUNDARY LINE SURVEY. |
| | |
| | 2. FOUNDATIONS FOR WALLS AND COLUMNS AT PROPERTY LINE |
| | SHALL NOT ENCROACH ONTO ADJOINING PROPERTY. PROVIDE |
| | STRUCTURAL DETAIL FOR FOUNDATIONS. |
| | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | 3. NOTE ON PLAN STATES SLIDING GATES WILL BE MOTORIZED. |
| | PROVIDE ELCTRICAL PLAN. |
| | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | |