| 2020-08-26 16:51:31 | PASSED UNDER MASTER 20040212 ? PER RB OK TO ISSUE SUB |
| | PERMIT |
| 2020-04-21 12:54:09 | PLEASE SPECIFY ON PLANS FOR EACH SUBMITTAL WHAT WORK IS |
| | TO BE COMPLETED, AND PROVIDE DRAWINGS, AND MANUFACTURER |
| | SPECIFICATION SHEETS FOR MATERIALS USED. |
| | |
| | THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH THE |
| | 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, |
| | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. |
| | |
| | PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND |
| | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF |
| | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE |
| | REMOVED FROM THE SITE DAILY MORE OFTEN TO REDUCE THE |
| | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. |
| | |
| | SMOKING SHALL BE PROHIBITED EXCEPT IN DESIGNATED |
| | EXTERIOR AREAS. ALL OTHER DEMOLITION OR CONSTRUCTION |
| | AREAS SHALL HAVE "NO SMOKING" SIGNS POSTED. WHERE |
| | SMOKING IS PERMITTED, SAFE RECEPTACLES FOR SMOKING |
| | MATERIALS SHALL BE PROVIDED. |
| | |
| | PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION |
| | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND |
| | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION |
| | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A |
| | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A |
| | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED |
| | BY EMAIL ([email protected]) OR IN WRITING (FAX: |
| | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE |
| | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.? |
| | |
| | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE |
| | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER |
| | SYSTEM AND/OR FIRE ALARM SYSTEM. |
| | |
| | THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM ALL |
| | ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. ADDRESS |
| | NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND AND SHALL |
| | NOT BE LESS THAN SIX (6) INCHES IN HEIGHT WITH A ONE |
| | (1) INCH STROKE FOR ALL BUILDINGS. |
| | |
| | 31.3.4.5.1* IN BUILDINGS OTHER THAN THOSE EQUIPPED |
| | THROUGHOUT WITH AN EXISTING, COMPLETE AUTOMATIC SMOKE |
| | DETECTION SYSTEM, SMOKE ALARMS SHALL BE INSTALLED IN |
| | ACCORDANCE WITH 9.6.2.10, AS MODIFIED BY 31.3.4.5.2, |
| | OUTSIDE EVERY SLEEPING AREA IN THE IMMEDIATE VICINITY |
| | OF THE BEDROOMS AND ON ALL LEVELS OF THE DWELLING UNIT, |
| | INCLUDING BASEMENTS. |
| | |
| | 31.3.4.1.1 APARTMENT BUILDINGS FOUR OR MORE STORIES IN |
| | HEIGHT OR WITH MORE THAN 11 DWELLING UNITS, OTHER THAN |
| | THOSE MEETING THE REQUIREMENTS OF 31.3.4.1.2, SHALL BE |
| | PROVIDED WITH |
| | A FIRE ALARM SYSTEM IN ACCORDANCE WITH SECTION 9.6, |
| | EXCEPT AS MODIFIED BY 31.3.4.2 THROUGH 31.3.4.5. |
| | |