| 2020-05-15 14:08:31 | REVIEWED BY JERRY SMITH. | | | 20040270 501 S FLAGLER DR # 200 | | | | | | PLUMBING COMMENTS: APPROVED | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | PROVISO | | | PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE AS A | | | DEFERRED SUBMITTAL A REVISED PLAN SHEET PO.1 WITH THE | | | FOLLOWING MODIFICATIONS. | | | 1.REMOVE REFERENCES TO A COFFEE MAKER AND THE | | | DISHWASHER IN PLUMBING FIXTURE SCHEDULE TO REFLECT | | | RESPONSE TO BUILDING COMMENTS IN RESPONSE LETTER DATED | | | 5/4/2020. | | | 2.REVISE TANK TYPE WATER CLOSET WITH ? INCH WATER | | | CONNECTION IN PLUMBING FIXTURE CONNECTION SCHEDULE TO | | | MATCH WATER CLOSET FLUSHOMETER TYPE WITH 1 INCH WATER | | | CONNECTION TO MATCH PLUMBING FIXTURE SCHEDULE AND RISER | | | DIAGRAM. | | | 3.ADD WORDS ?LEAD FREE? TO THE SD-2 BACKFLOW PREVENTORS | | | NOTED IN THE PLUMBING FIXTURE CONNECTION SCHEDULE. | | | SUBMITTAL SHALL BE SUBMITTED, APPROVED AND ON SITE | | | PRIOR TO FIRST INSPECTION. PROCEED AT YOUR OWN RISK. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-246-0882 MOBILE | | | | | | 20040270 501 S FLAGLER DR # 200 | | | | | | |
|