| Date |
Text |
| 2020-04-16 08:06:38 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SIXTH EDITION (2017) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THIS POOL APPEARS TO BE AN AMENITY OF A RESIDENTIAL |
| | GROUP R OCCUPANCY AND MAY BE REQUIRED TO COMPLY THE |
| | 2017 FBC ACCESSIBILITY. SHOW HOW THE NEW POOL WILL |
| | COMPLY WITH FBC ACCESSIBILITY SECTION 242.2 SWIMMING |
| | POOLS. |
| | AT LEAST TWO ACCESSIBLE MEANS OF ENTRY SHALL BE |
| | PROVIDED FOR SWIMMING POOLS. ACCESSIBLE MEANS OF ENTRY |
| | SHALL BE SWIMMING POOL LIFTS COMPLYING WITH 1009.2; |
| | SLOPED ENTRIES COMPLYING WITH 1009.3; TRANSFER WALLS |
| | COMPLYING WITH 1009.4; TRANSFER SYSTEMS COMPLYING WITH |
| | 1009.5; AND POOL STAIRS COMPLYING WITH 1009.6. AT LEAST |
| | ONE ACCESSIBLE MEANS OF ENTRY PROVIDED SHALL COMPLY |
| | WITH 1009.2 OR 1009.3. |
| | |
| | EXCEPTIONS: |
| | |
| | 1. WHERE A SWIMMING POOL HAS LESS THAN 300 LINEAR FEET |
| | (91 M) OF SWIMMING POOL WALL, NO MORE THAN ONE |
| | ACCESSIBLE MEANS OF ENTRY SHALL BE REQUIRED PROVIDED |
| | THAT THE ACCESSIBLE MEANS OF ENTRY IS A SWIMMING POOL |
| | LIFT COMPLYING WITH 1009.2 OR SLOPED ENTRY COMPLYING |
| | WITH 1009.3. |
| | |
| | 2. WAVE ACTION POOLS, LEISURE RIVERS, SAND BOTTOM |
| | POOLS, AND OTHER POOLS WHERE USER ACCESS IS LIMITED TO |
| | ONE AREA SHALL NOT BE REQUIRED TO PROVIDE MORE THAN ONE |
| | ACCESSIBLE MEANS OF ENTRY PROVIDED THAT THE ACCESSIBLE |
| | MEANS OF ENTRY IS A SWIMMING POOL LIFT COMPLYING WITH |
| | 1009.2, A SLOPED ENTRY COMPLYING WITH 1009.3, OR A |
| | TRANSFER SYSTEM COMPLYING WITH 1009.5. |
| | |
| | 3. CATCH POOLS SHALL NOT BE REQUIRED TO PROVIDE AN |
| | ACCESSIBLE MEANS OF ENTRY PROVIDED THAT THE CATCH POOL |
| | EDGE IS ON AN ACCESSIBLE ROUTE. |
| | |
| | ADVISORY 242.2 SWIMMING POOLS. WHERE MORE THAN ONE |
| | MEANS OF ACCESS IS PROVIDED INTO THE WATER, IT IS |
| | RECOMMENDED THAT THE MEANS BE DIFFERENT. PROVIDING |
| | DIFFERENT MEANS OF ACCESS WILL BETTER SERVE THE VARYING |
| | NEEDS OF PEOPLE WITH DISABILITIES IN GETTING INTO AND |
| | OUT OF A SWIMMING POOL. IT IS ALSO RECOMMENDED THAT |
| | WHERE TWO OR MORE MEANS OF ACCESS ARE PROVIDED, THEY |
| | NOT BE PROVIDED IN THE SAME LOCATION IN THE POOL. |
| | DIFFERENT LOCATIONS WILL PROVIDE INCREASED OPTIONS FOR |
| | ENTRY AND EXIT, ESPECIALLY IN LARGER POOLS. |
| | ADVISORY 242.2 SWIMMING POOLS EXCEPTION 1. POOL WALLS |
| | AT DIVING AREAS AND AREAS ALONG POOL WALLS WHERE THERE |
| | IS NO POOL ENTRY BECAUSE OF LANDSCAPING OR ADJACENT |
| | STRUCTURES ARE TO BE COUNTED WHEN DETERMINING THE |
| | NUMBER OF ACCESSIBLE MEANS OF ENTRY REQUIRED. |
| | |
| | 2) SHOW COMPLIANCE WITH 2017 FBC-ACCESSIBILITY SECTION |
| | 206 ACCESSIBLE ROUTES. |
| | 206.1 GENERAL. |
| | ACCESSIBLE ROUTES SHALL BE PROVIDED IN ACCORDANCE WITH |
| | 206 AND SHALL COMPLY WITH CHAPTER 4. |
| | |
| | 206.2.2 WITHIN A SITE. |
| | AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE |
| | BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, |
| | AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. |
| | |
| | |
| | COMMUNITY POOLS THAT ARE ASSOCIATED WITH A PRIVATE |
| | RESIDENTIAL COMMUNITY THAT DO NOT RECEIVE GOVERNMENTAL |
| | FINANCIAL ASSISTANCE OR SPONSORSHIP AND ARE LIMITED TO |
| | THE EXCLUSIVE OF RESIDENTS AND THEIR GUESTS ARE NOT |
| | COVERED BY THE ADA ACCESSIBILITY REQUIREMENTS, |
| | INCLUDING PROVISIONS FOR POOL LIFTS OR SLOPED ENTRIES. |
| | IF A SWIMMING POOL LOCATED IN A RESIDENTIAL COMMUNITY |
| | IS MADE AVAILABLE TO THE PUBLIC FOR RENTAL OR USE IT IS |
| | REQUIRED TO COMPLY WITH TITLE II OF THE ADA. SPECIFY ON |
| | THE PLANS THE FORMER OR SHOW COMPLIANCE WITH THE LATTER |
| | STATEMENTS. SEE DECLARATORY STATEMENT, DS 2013-011. |
| | |
| | NOTE: ALTHOUGH THE POOL MAY NOT HAVE TO APPLY WITH THE |
| | FLORIDA ACCESSIBILITY CODE, IT WILL STILL NEED NEED TO |
| | COMPLY WITH FAIR HOUSING. |
| | |
| | 2) PORTIONS OF THIS PROPERTY IS LOCATED IN A SPECIAL |
| | FLOOD HAZARD AREA, "AE" WITH A BFE OF 14.1' |
| | NAVD(INCLUDING THE CITY'S 2 FOOT FREEBOARD). ALL OF THE |
| | POOL EQUIPMENT LOCATED IN THE SFHA IS REQUIRED TO BE |
| | LOCATED ABOVE THE BFE OR BE FLOOD PROOFED. |
| | |
| | 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A |
| | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE |
| | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE |
| | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND |
| | KEEP THEM WITH THE SUBMITTALS. |
| | |
| | |
| | |
| | |