Plan Review Notes
Plan Review Notes For Permit 20040217
Permit Number 20040217
Review Stop G
Sequence Number 3
Notes
Date Text
2020-06-05 12:04:453RD REVIEW FBC RES 2017
 PERMIT 20040217
 6/5/2020
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS FROM THE 2ND REVIEW BELOW WILL BE MARKED AS
 PASSED OR FAILED. SEE NOTES ADDED FOR FAILED COMMENTS.
  
 1) PASSED.
 2) PASSED.
  
 3.) PASSED. LIST THE BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO THE 2017
 FBC-FUEL GAS SECS.401.8, 402.2, AND TABLES 402.4 (1)
 THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2413.4
 AND TABLES G2413.4 (1 ) THROUGH G2413.4 (21).
  
 4.) PASSED SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (GAS METER / MP REGULATOR / LP TANK) TO THE
 MOST REMOTE OUTLET IN THE BUILDING AND / OR SYSTEM PER
 THE 2017 FBC-FUEL GAS SEC.402.4.1, 402.4.2, OR 2017
 FBC-RES. SEC. G 2413.4.1, G2413.4.2.
  
 5.) FAILED SUBMIT CALCULATIONS FOR COMBUSTION AIR.
 PROVIDE VERIFICATION & CALCULATIONS AS TO HOW THE
 REQUIREMENTS ARE BEING MET. PROVIDE THE CODE SECTIONS
 FROM THE GAS CODE THAT YOU ARE USING IN THE DESIGN OF
 THE COMBUSTION AIR REQUIREMENTS PER THE 2017 FBC-FUEL
 GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR 2017
 FBC-RES. SEC.G 2407.1 AND G2439.4 (CLOTHES DRYERS).
 SECTION G2407.1- MAKEUP AIR NOT PROVIDED FOR THE
 CLOTHES DRYER. DETAIL 4/P1 INDICATES OUTDOOR AIR WHICH
 WOULD REQUIRE AN OPENING OR OPENINGS TO THE EXTERIOR
 PER SECTIONS G2407.6- G2407.7. FBC RES.
  
 6) PASSED
  
 7) FAILED. SUBMIT TWO COPIES OF A DETAIL SHOWING THE
 TYPE OF VENT, LOCATION, SIZE, TERMINATION POINT, HEIGHT
 ABOVE THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S)
 PER 2017 FBC-FUEL GAS SECS. 502 THRU 505 OR 2017
 FBC-RES. SEC.G2426 THROUGH G2439. THE REVISED DETAIL ON
 P1 DOES NOT SHOW THE METAL FLUE VENT SIZE, TOTAL VENT
 LENGTH AND TERMINATION POINT WITH PROPER TERMINATION
 CAP. PLEASE PROVIDE THE CORRECT RINNAI MODEL NUMBER ON
 THE PLAN AND REVIEW THE VENTING SPECIFICATIONS ON PAGE
 7-8 OF THE MANUFACTURER?S SPECIFICATIONS. THE VENT FLUE
 IS NOT REQUIRED [PER THE SPECS BUT PROPER CLEARANCES
 ARE. PLEASE SHOW COMPLIANCE.
  
 8) PASSED. SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54,
 NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND
 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES
 SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS
 FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT
 THE TIME OF INSPECTION. FGC SEC.305.1, FBC-RES.
 SEC.G2408.1.
  
 9) FAILED. SUBMIT TWO COPIES OF THE APPLICABLE SIZING
 TABLES USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON
 THE PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S)
 FROM THE GAS CODE OR OTHER STANDARD THAT WERE USED IN
 THE DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017
 FBC-FUEL GAS SECS. 401.4, 401.8, 402.3, AND TABLES
 402.4 (1) THRU 402.4 (37) OR 2017 FBC-RES. SEC.
 G2413.3, G2412.8, G2413.1, G2413.2, & G2413.3. TABLE
 402.4(9) CALLED OUT ON THE ISO IS FOR SEMI-RIGID COPPER
 TUBING, BUT SCHEDULE 40 METALLIC PIPE IS CALLED OUT FOR
 INSTALLATION. PLEASE NOTE THAT DETAIL 1/P-2 DOES NOT
 SHOW THE GAS LINE RUNS TO THE WATER HEATER, STOVE, AND
 THE DRYER. PLEASE NOTE THAT THE GAS PIPING INSTALLATION
 MAY BE DONE UNDER A SEPARATE PERMIT IF THAT WOULD
 FACILITATE THE ISSUANCE OF THE MAIN PERMIT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  