| 2020-05-14 07:58:50 | REVIEWED BY JERRY SMITH. |
| | |
| | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 20031435 140 MONROE DR |
| | |
| | 2ND REVIEW |
| | PLUMBING COMMENTS: DENIED |
| | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS |
| | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY |
| | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW |
| | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. |
| | |
| | COMMENT #1: CORRECTED |
| | COMMENT #2: SECOND REQUEST |
| | A.(RE: HYDRAULIC CALCULATIONS; PER WPB FBC 107.2. 1 AND |
| | APSP-7-2013, INCLUDE THE HEAD LOSS FOR THE POOL HEATER |
| | AS WELL AS THE VALVES AND FITTINGS.) TO BE CLEAR AS |
| | REQUIRED BY WPB FBC 107.2. 1 AND APSP-7-2013, |
| | CALCULATIONS SHALL INCLUDE THE HEAD LOSS FOR THE POOL |
| | HEATER AS WELL AS THE VALVES AND FITTINGS. |
| | B.(ADDITIONALLY, ALL EQUIPMENT SUBMITTALS SHALL BE |
| | CLEAR, EASILY READ AND SHALL INCLUDE ALL PERTINENT |
| | TECHNICAL INFORMATION INCLUDING BUT NOT LIMITED TO |
| | HYDRAULIC FLOW AND HEAD LOSS.) TO BE CLEAR AS REQUIRED |
| | BY WPB FBC 107.2. 1 AND APSP-7-2013, EQUIPMENT |
| | SUBMITTALS SHALL |
| | 1.INCLUDE HYDRAULIC FLOW AND HEAD LOSS |
| | 2.BE EASILY READ |
| | 3.INDICATE SELECTED MODEL NUMBER IF THERE IS MORE THAN |
| | ONE LISTED IN SUBMITTAL |
| | |
| | COMMENT #3: CORRECTED |
| | |
| | |
| | GAS COMMENTS: GAS PLAN AND PERMIT REQUIRED |
| | POOL HEATER IS GAS. A GAS PLAN HAS NOT BEEN INCLUDED IN |
| | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN |
| | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS |
| | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE |
| | RELATED WORK. PROVIDE COMPLETE PLANS, APPLIANCE/ |
| | EQUIPMENT SPECIFICATIONS AND GAS RISER THAT REFLECT THE |
| | ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC |
| | SEC. 107.2.1. |
| | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE |
| | FBC-R, SEC. G2404.3. |
| | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL |
| | GAS SEC. 301.3. |
| | A SEPARATE PERMIT AND PLANS ARE REQUIRED FOR THE GAS |
| | INSTALLATION OR MODIFICATION OF SYSTEM. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE |
| | DESIGNER IN ACCORDANCE WITH FAC AND FS REQUIREMENTS. |
| | |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-246-0882 MOBILE |
| | |
| | 20031435 140 MONROE DR |
| | |
| | |