| Plan Review Notes For Permit 20030973 |
| Permit Number |
20030973 |
|
| Review Stop |
B |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2020-08-21 10:07:48 | ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | 3RD REVIEW - YOU STATED IN YOUR RESUBMITTAL COMMENTS | | | "EXTERIOR WALLS ARE EXISTING" EXTERNAL WALLS MAY BE | | | EXISTING BUT, THE ADDITION DOES NOT HAVE A PERMIT | | | (02041430 IS EXPIRED) - IF THIS IS NOT THE PERMIT FOR | | | THE ADDITION YOU NEED TO APPLY FOR A NEW PERMIT FOR THE | | | ADDITION BEFORE PERMITING A REVISION FOR A VIOLATION. | | | ON YOUR SITE PLAN THE SCOPE OF WORK SAYS "ADDITION". | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW THE EXTERIOR DOOR LANDING FOR THE | | | SLIDING DOOR AT THE MASTER BED ROOM TO COMPLY WITH FBC | | | R311.3.2 AND R311.3 | | | 2) DRAWING A-1 SHOWS ADDITION AS CMU WALL - DRAWING S-1 | | | SHOWS WOOD FRAMED WALL - PLEASE CLEARIFY - DETAILS | | | SHOULD MATCH. | | | 3) PLEASE PROVIDE THE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE ROOFING SYSTEM TO BE USED. | | | 4) JOB DESCRIPTION ON THE BUILDING PERMIT APPLICATION | | | NEEDS TO REFLECT THE DRAWINGS (SITE PLAN SHOWS SCOPE OF | | | WORK AS ADDITION). | | | 5) DRAWING E-1 = THE SMOKE DETECTOR IN FRONT OF THE | | | BATHROOM SHOULD BE SHOWN IN THE HALLWAY OF THE BEDROOMS | | | FBC R314.3 |
|