2020-03-27 14:24:331ST REVIEW FBC-2017 PLUMBING
 PERMIT #20030973
 3/27/20
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P-1:THE WYE FITTINGS FOR THE KITCHEN SINK AND
 CLOTHES WASHER DRAINS ARE DIRECTING THE WASTE FLOWS
 UPSTREAM INTO THE MAIN DRAIN INSTEAD OF DOWNSTREAM-
 SECTION P3005.1 FBC RES.
  
 2) P-1: PROVIDE A SANITARY ISOMETRIC DRAWING- SECTION
 P3005.4 FBC RES AND SECTION 107.3.5.3 WPB RES.
  
 3) P-1: SHOW HOW ACCESS AND VENTILATION WILL BE
 PROVIDED FOR THE STUDOR VENTS AT THE TUB/SHOWER, AND
 THE SHOWER IN MASTER BATH- SECTION P3114.5 FBC RES.
  
 4) SUBMIT A SPEC SHEET FOR THE TANKLESS WATER HEATER-
 SECTION P2801.3 & M2005 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  