Plan Review Notes
Plan Review Notes For Permit 20030965
Permit Number 20030965
Review Stop Z
Sequence Number 1
Notes
Date Text
2020-07-31 15:33:39FAILED
  
 1) PROVIDE A PROVIDE A SURVEY, PREPARED BY A FLORIDA
 LICENSED SURVEYOR, WHICH SHOWS THE POLE LOCATION AND
 THE RIGHT-OF-WAY LINE SO THAT STAFF CAN VERIFY THAT THE
 WIRELESS COMMUNICATION FACILITY IS WITHIN THE
 RIGHT-OF-WAY AND NOT ON PRIVATE PROPERTY. THE
 ENGINEERING PLAN INCORRECTLY SHOWS THE RIGHT-OF-WAY
 LINE. STAFF FOUND AN OLD SURVEY AND WHEN COMPARING THE
 SURVEY TO THE PERMIT SHOWS THE POLE, AND ELECTRIC BOX,
 ENCROACHING PRIVATE PROPERTY, WHICH IS NOT PERMITTED
 UNLESS THE CITY HAS APPROVED A WIRELESS COMMUNICATION
 FACILITIES PERMIT.
  
 2) PROVIDE A COPY OF THE FDOT APPROVAL IF THE SURVEY
 SHOWS THE PROPOSED WIRELESS COMMUNICATION FACILITY IN
 THE RIGHT-OF-WAY.
  
 3) THE PLANS SUBMITTED WITH THE PERMIT SHOW THAT THE
 PROPOSED WIRELESS FACILITY (POLE) DOES NOT MEET THE
 CITY OF WEST PALM BEACH CONCEALMENT (STEALTH) OR STYLE
 AND POSSIBLY HEIGHT REQUIREMENTS LISTED IN SECTIONS
 78-411(E), 78-411(F) AND 78-411(G) OF THE CITY CODE.
 PROVIDE A POLE THAT MEETS THE CITY CODE REQUIREMENTS.
 NOTE: VERIZON HAS SHOWN POLES ON OTHER APPLICATIONS FOR
 OTHER LOCATIONS WITHIN THE CITY THAT MEET THE CITY CODE
 REQUIREMENTS.
  
 4) THE POWER DRAW IS SHOWN FROM A POLE ALONG THE ALLEY
 TO THE EAST OF THE PROPERTY. THE SURVEY YOUR PROVIDE
 NEEDS TO CLEARLY SHOW THAT THE UNDERGROUND POWER IS
 WITHIN THE ALLEY (CITY WIRELESS COMMUNICATION FACILITY
 IN THE RIGHT-OF-WAY PERMIT IS REQUIRED FOR THIS WORK)
 AND NOT ON PRIVATE PROPERTY. THE STAFF SURVEY SHOWS NO
 UTILITY EASEMENT ON THE PRIVATE PROPERTY, SO YOU MAY
 NOT BORE UNDER THE LOT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  