| Date |
Text |
| 2020-05-29 08:56:52 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): |
| | 1. PROVIDE PHOTOS OF EACH ELEVATION WITH OPENING LABELS |
| | MATCHING THE WINDOW SCHEDULE AND SITE PLAN. IF NOT |
| | POSSIBLE FOR EACH ELEVATION, PROVIDE MORE THAN ONE |
| | PHOTO. |
| | 2. THE FRONT DOOR IS INAPPROPRIATE. REVISE THE DOOR TO |
| | BE A MISSION APPROPRIATE DOOR. PROVIDE GRAPHIC OF |
| | PROPOSED DOOR. |
| | 3. THE TWO WINDOWS (PAIRED) WITH A 12/12 LITE PATTERN |
| | NEED TO BE REMOVED. A TRIPLE PAIRED WINDOW WITH 6/1 |
| | LITE PATTERN WILL NEED TO BE INSTALLED. THE WINDOWS AND |
| | MULLION WILL NEED TO BE SIZED TO WHAT WAS EXISTING |
| | BEFORE THE WINDOWS WERE REPLACED. |
| | 4. THE TWO WINDOWS ON THE SECOND FLOOR UNDER THE PESKY |
| | CYPRESS BRACKETS WILL NEED TO BE REMOVED. A TRIPLE |
| | PAIRED WINDOW WITH 6/1 LITE PATTERN WILL NEED TO BE |
| | INSTALLED. THE WINDOWS AND MULLION WILL NEED TO BE |
| | SIZED TO WHAT WAS EXISTING BEFORE THE WINDOWS WERE |
| | REPLACED. |
| | 5. THE WINDOW LOCATED ABOVE THE BALCONY WILL NEED TO BE |
| | REMOVED. A PAIRED FRENCH DOOR WITH 10-LITE EACH WILL |
| | NEED TO BE INSTALLED. |
| | 6. ALL WINDOWS WILL NEED TO HAVE WINDOW TRIM AND SILL |
| | RECONSTRUCTED. |
| | 7. ALL WINDOWS REQUIRING A MULLION SHALL HAVE A MULLION |
| | TO MATCH THE EXISTING/ORIGINAL MULLION WIDTH. THIS WAS |
| | LIKELY BETWEEN 4 AND 6 INCHES. |
| | 8. PROVIDE THE MUNTIN DETAIL FOR EACH PRODUCT BEING |
| | USED. LAWSON HAS A DIFFERENT MUNTIN PROFILE AVAILABLE |
| | COMPARED TO JELD-WEN AND SILVER LINE. |
| | |
| | PROPOSED CONDITIONS, SUBJECT TO CHANGE: |
| | 1. ALL WINDOWS NEED TO BE SIZED TO FIT THE ORIGINAL |
| | WINDOW FRAME OPENING. ALL WINDOWS SHALL MATCH THE |
| | INSET/LOCATION/DEPTH OF THE ORIGINAL WINDOWS WITHIN THE |
| | FRAME OPENING. |
| | 2. ALL NEW STREET-FACING WINDOWS NEED TO HAVE CLEAR |
| | GLASS ONLY. |
| | 3. THE SMALL 8-LITE WINDOWS ON EITHER SIDE OF THE FRONT |
| | DOOR SHALL REMAIN AND BE REPAIRED AS NEEDED. |
| | |
| | |
| | THE FOLLOWING ITEMS TO ADDRESS MAY NOT BE COMPLETE |
| | GIVEN THE LACK OF INFORMATION PROVIDED TO STAFF. |
| | REUSING EXISTING WINDOWS IN OPENINGS THAT NEED TO BE |
| | REVERTED BACK TO THEIR ORIGINAL STATE MAY BE POSSIBLE. |
| | |
| | AARON BORNGRABER |
| | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES |
| | PLANNING DIVISION |
| | [email protected] | OFFICE: 561.822.1428 | TTY: |
| | 800.955.8771 |
| | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, |
| | FL 33402 |
| | |