| Date |
Text |
| 2020-03-31 16:07:55 | FAILED |
| | |
| | 1) THE SIGN INCLUDES NOT ONLY THE TD AND THE AMERITRADE |
| | TEXT, BUT ALSO THE DECK CABINET, WHICH MAKES THE ENTIRE |
| | SIGN 23.8 SQUARE FEET. |
| | |
| | 2) THE PROPOSED SIGN IS A FASCIA SIGN IN THE ROSEMARY |
| | SQUARE TENANT SIGN CRITERIA. FASCIA SIGNS ARE PERMITTED |
| | ON A CASE-BY-CASE BASIS FOR SINGLE HEIGHT TENANTS |
| | WITHOUT ARCADES (STOREFRONT TYPE 3). SIGNS PERMITTED ON |
| | A CASE-BY-CASE BASIS REQUIRE THE APPROVAL OF A WAIVER |
| | I, WHICH IS WRITTEN APPROVAL FROM CITYPLACE RETAIL ON |
| | THEIR LETTERHEAD. |
| | |
| | 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT THE WALL SIGNS (WHICH INCLUDE FASCIA SIGNS) BE |
| | BALANCED WITHIN THE SIGN SPACE. PLEASE PROVIDE THE |
| | DIMENSIONS FROM THE SIGN TEXT TO EACH END OF THE DECK |
| | CABINET. THESE DIMENSIONS MUST BE EQUAL. |
| | |
| | 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PROHIBIT |
| | VISIBLE WIRING. THE ELEVATION DRAWING SHOWS VISIBLE |
| | WIRES RUNNING FROM THE BACK OF EACH LETTER TO THE DECK |
| | CABINET. |
| | |
| | 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT |
| | FASCIA SIGNS TO BE BETWEEN NINE (9) AND TWELVE FEET |
| | FROM FINISHED GRADE. THE ELEVATION PLAN DOES NOT |
| | PROVIDE THE HEIGHT OF THE SIGN FROM GRADE. PROVIDE THE |
| | DIMENSIONS SO THAT STAFF CAN VERIFY THE SIGN PLACEMENT. |
| | |
| | 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A |
| | MAXIMUM SIGN PANEL (THE DECK CABINET) AND LETTER HEIGHT |
| | OF 18 INCHES FOR A FASCIA SIGN UNLESS CITYPLACE RETAIL |
| | IS GRANTED A WAIVER II (MINOR PLANNED DEVELOPMENT |
| | AMENDMENT). THE WAIVER II MAY INCREASE THE SIGNS |
| | DIMENSION BY UP TO 25 PERCENT, SO THE SIGN PANEL (THE |
| | DECK CABINET) AND LETTER HEIGHT COULD BE UP TO 22.5 |
| | INCHES. NOTE: THE PROPOSED SIGN IS 23 INCHES IN HEIGHT. |
| | |
| | 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT LETTER CHANNELS ARE TO BE STUD MOUNTED A MAXIMUM |
| | ONE (1) INCH FROM THE WALL. THE PROPOSED DESIGN WITH A |
| | DECK CABINET MOUNTED TO THE WALL AND THE CHANNEL |
| | LETTERS MOUNTED TO THE DECK PANEL DOES IS NOT |
| | PERMITTED. |
| | |
| | 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE |
| | STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR |
| | BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE |
| | PLANS. |
| | |
| | PERMITTED: 88 SF |
| | PROPOSED: 23.8 SF |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |