| Plan Review Notes For Permit 20030563 |
| Permit Number |
20030563 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2020-10-09 10:02:25 | NEW APT. BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) REVISED DRAWING (S7.1) SHOWS WIND DESIGN | | | CALCULATIONS USING ASCE 7-16 - SHOULD BE USING ASCE | | | 7-10 PER FBC CHAPTER 35 | | | | | | PROVISO: | | | A) SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE | | | REQUIRED FOR: | | | LIGHT POLES/SITE LIGHTING | | | PARKING LOT | | | DETACHED STRUCTURES - GAZEBO ETC. | | | B) PROVIDE FLOORING IIC AND STC ACOUSTICAL TEST REPORTS | | | FOR REVIEW FOR THE TILE FLOORING BEFORE FLOORING | | | INSTALLATION. |
|