2020-03-13 19:10:2303/13/20 1ST PLUMBING/IRRIGATION REVIEW**DENIED** WITH
 COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THIS BUILDING WAS CONSTRUCTED UNDER THE REQUIREMENTS
 OF THE FAIR HOUSING ACT. INDICATE ON THE PLANS WHICH
 DESIGN SPECIFICATION ( "A" OR 'B" OF THE ACT) WAS USED
 IN THE ORIGINAL DESIGN IN THIS UNIT.
  
 2. PLEASE PROVIDE DETAIL OF THE SHOWER PAN TYPE OR
 MATERIAL YOU ARE USING CONFORMING WHIT 2017 FBC SECTION
 417.5.2.
  
 3. THE FAIR HOUSING ACT PROVIDES TWO SETS OF
 SPECIFICATIONS TO DESIGN BATHROOMS THAT ARE USABLE BY
 PEOPLE WITH DISABILITIES. THOUGH THERE ARE OTHER
 DIFFERENCES, SPECIFICATION B BATHROOMS OFFER GREATER
 ACCESS TO THE TUB THAN SPECIFICATION A BATHROOMS.
  
 IF THE SPECIFICATION A DESIGN IS SELECTED, ALL
 BATHROOMS IN THE UNIT MUST COMPLY WITH SPECIFICATION A
 STANDARDS (SECTION 7.14). THIS INCLUDES ACCESS TO ALL
 FIXTURES IN EACH SPECIFICATION A BATHROOM (E.G., TWO
 LAVATORIES IN ONE BATHROOM WOULD BOTH NEED TO MEET FHA
 REGULATIONS).
  
 IF THE SPECIFICATION B DESIGN IS SELECTED, ONLY ONE
 BATHROOM IN THE UNIT, AND ONLY ONE OF EACH TYPE OF
 FIXTURE WITHIN THE BATHROOM, MUST COMPLY WITH
 SPECIFICATION B STANDARDS (SECTION 7.15). ALL OTHER
 BATHROOMS IN THE UNIT MUST MEET THE USABLE BATHROOM
 REQUIREMENTS (SECTION 7.11), EXEMPTING MANEUVERING
 CLEARANCES AND CLEAR FLOOR SPACE REQUIREMENTS AT
 FIXTURES.
  
 4. THE CITY OF WEST PALM BEACH BUILDING DEPARTMENT
 PROVIDES AN OPTION FOR THE CHANGING OF AN FHA
 COMPLIANCE STRUCTURE. THE OWNER AND DESIGNER OF RECORD
 ACKNOWLEDGE THAT THE PROPOSED BATHROOM DESIGN DOES NOT
 MEET THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES. THE OWNER AGREES TO REVERT THE UNIT BACK TO
 COMPLIANCE AT THE TIME OF SALE IF SO, REQUESTED BY THE
 BUYER. THIS WILL BE IN A LETTER TYPE FORMAT SIGNED AND
 NOTARIZED BY THE OWNER. WE PROVIDE A SAMPLE LETTER AND
 IT MUST BE SUBMITTED TO THE BUILDING DEPARTMENT OF THE
 CITY OF WPB.
  
 5. THE PLAN IS TOO SMALL TO READ NOTES, PLANS SHALL BE
 DRAWN TO A MINIMUM 1/8 INCH SCALE PER THE WPB AMENDMENT
 TO FBC SEC. 107.2.1.3 QUALITY OF BUILDING PLANS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  