 1ST REVIEW FBC-2017 PLUMBING
 PERMIT #20030483
 3/26/20
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-2: THE WASHING MACHINE DRAIN CANNOT CONNECT
 INTO THE SHOWER FIXTURE DRAIN, AND MUST MAKE CONNECTION
 INTO THE 3" DRAIN DOWNSTREAM OF THE SHOWER AND ALL
 OTHER BATH FIXTURES- PLEASE SEE SECTION P3108.1 FBC RES
 HORIZONTAL WET VENT. THE WASHER DRAIN CANNOT BE PART OF
 THE HORIZONTAL WET VENT AND SHALL BE INDIVIDUALLY
 VENTED.
  
 2) A-2; SHOW DOUBLE LAVATORY DRAINS AND LAV DRAIN SIZES
 IN THE PLUMBING RISER DRAWING- SECTION P3005.4 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  