| Plan Review Notes For Permit 20030483 |
| Permit Number |
20030483 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-03-24 15:23:49 | SFR ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS, | | | SLIDING DOORS ETC. ALL PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER | | | OF RECORD. | | | 2) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT OR | | | PROVIDE A SOIL STATEMENT ON THE DRAWINGS STATING THE | | | SOIL BEARING CAPACITY. FBC R401.4 | | | 3) PLEASE PROVIDE A MIAMI DADE OR FLORIDA STATE PRODUCT | | | APPROVAL FOR THE ROOFING TO BE USED. 107.2.1.1 | | | 4) DRAWING A-3 TYP. WALL SECTION - SHOWS "ASPHALT TILE" | | | ON THE ROOF. WHAT IS ASPHALT TILE? SLOPE WILL NOT ALLOW | | | ASPHALT SHINGLES. FBC R905.2.2 | | | 5) DRAWING A-3 TYP. WALL SECTION - SHOWS SCREEN VENTS | | | AT 8 FOOT SPACING, SCREEN VENT SHOULD BE CONTINUOUS TO | | | ALLOW VENTILATION BETWEEN EACH JOIST. FBC R806.1 | | | |
|