| 2020-07-09 12:17:26 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | |
| | 20030099 3111 S DIXIE HWY |
| | |
| | PLUMBING COMMENTS: DENIED |
| | ENGINEER HAS REMOVED ALL DRAINAGE PIPING, FLOOR DRAINS, |
| | TRENCH DRAINS AND THE OIL INTERCEPTOR FROM THE PLANS |
| | AND PROVIDED A NOTE ON PLAN SHEET P-2.0 REGARDING THE |
| | DISCHARGE OF LIQUID WASTE FROM THE TRASH COMPACTOR. |
| | THERE IS NO ISSUE TAKEN WITH THIS CONCEPT. THE NOTE |
| | NEEDS TO BE REVISED TO REFLECT THE FACT THAT THERE WILL |
| | BE NO DRAINS AS IT SUGGESTS DISCHARGE TO TRENCH DRAIN. |
| | HOWEVER, THE ARCHITECTURAL PLANS DO NOT IN ANY WAY |
| | ADDRESS THE THE DRAINAGE ISSUE IN THE STRUCTURE NOW |
| | THAT THE DRAINS HAVE BEEN REMOVED. PER WPB FBC 107.2.1, |
| | PROVIDE ARCHITECTURAL DRAWINGS THAT ALLOW FOR RUNOFF OF |
| | WATER FROM THE FLOORS IN A WAY THAT IS COMPLIANT WITH |
| | ALL PROVISIONS OF THE FLORIDA BUILDING CODE INCLUDING, |
| | BUT NOT LIMITED TO FBC AND FBC PL |
| | |
| | END OF COMMENTS. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE |
| | DESIGNER IN ACCORDANCE WITH FAC AND FS. |
| | |