| Date |
Text |
| 2020-03-05 18:18:35 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SIXTH EDITION (2017) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) SUBMIT A RECEIPT FROM THE PALM BEACH COUNTY HEALTH |
| | TO SHOW THAT AN APPLICATION AND THE REQUIRED |
| | INFORMATION HAS BEEN SUBMITTED TO THEM. FLORIDA |
| | STATUTES 514.03, APPROVAL NECESSARY TO CONSTRUCT, |
| | DEVELOP, OR MODIFY PUBLIC SWIMMING POOLS OR PUBLIC |
| | BATHING PLACES. |
| | (1) A PERSON OR PUBLIC BODY DESIRING TO CONSTRUCT, |
| | DEVELOP, OR MODIFY A PUBLIC SWIMMING POOL MUST SUBMIT |
| | AN APPLICATION, CONTAINING THE INFORMATION REQUIRED |
| | UNDER S. 514.031(1)(A)1.-6. TO THE DEPARTMENT FOR AN |
| | OPERATING PERMIT BEFORE FILING AN APPLICATION FOR A |
| | BUILDING PERMIT UNDER S. 553.79. A COPY OF THE FINAL |
| | INSPECTION REQUIRED UNDER S. 514.031(1)(A)5. SHALL BE |
| | SUBMITTED TO THE DEPARTMENT UPON RECEIPT BY THE |
| | APPLICANT. THE APPLICATION SHALL BE DEEMED INCOMPLETE |
| | PURSUANT TO S. 120.60 UNTIL SUCH COPY IS SUBMITTED TO |
| | THE DEPARTMENT. |
| | (2) LOCAL GOVERNMENTS OR LOCAL ENFORCEMENT DISTRICTS |
| | MAY DETERMINE COMPLIANCE WITH THE GENERAL CONSTRUCTION |
| | STANDARDS OF THE FLORIDA BUILDING CODE, PURSUANT TO S. |
| | 553.80. LOCAL GOVERNMENTS OR LOCAL ENFORCEMENT |
| | DISTRICTS MAY CONDUCT PLAN REVIEWS AND INSPECTIONS OF |
| | PUBLIC SWIMMING POOLS AND PUBLIC BATHING PLACES FOR |
| | THIS PURPOSE. |
| | |
| | 2) THIS PUBLIC POOL IS ASSOCIATED WITH AN R-2 OCCUPANCY |
| | AND IS SUBJECT TO THE FBC ACCESSIBILTY FOR ACCESSIBILE |
| | MEANS OF ENTRY PER SECTION 242 UNLESS IT IS EXEMPT. |
| | COMMUNITY POOLS THAT ARE ASSOCIATED WITH A PRIVATE |
| | RESIDENTIAL COMMUNITY THAT DO NOT RECEIVE GOVERNMENTAL |
| | FINANCIAL ASSISTANCE OR SPONSORSHIP AND ARE LIMITED TO |
| | THE EXCLUSIVE OF RESIDENTS AND THEIR GUESTS ARE NOT |
| | COVERED BY THE ADA ACCESSIBILITY REQUIREMENTS, |
| | INCLUDING PROVISIONS FOR POOL LIFTS OR SLOPED ENTRIES. |
| | IF A SWIMMING POOL LOCATED IN A RESIDENTIAL COMMUNITY |
| | IS MADE AVAILABLE TO THE PUBLIC FOR RENTAL OR USE IT IS |
| | REQUIRED TO COMPLY WITH TITLE II OF THE ADA. SPECIFY ON |
| | THE PLANS THE FORMER OR SHOW COMPLIANCE WITH THE LATTER |
| | STATEMENTS. SEE DECLARATORY STATEMENT, DS 2013-011. |
| | |
| | 3) DUE TO THE STRUCTURAL NATURE OF THIS PROJECT AND THE |
| | REQUIREMENTS FOR SHORING, A THRESHOLD INSPECTOR WILL BE |
| | REQUIRED. THRESHOLD BUILDING / FL S. S. 553.71(7) |
| | "THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS |
| | GREATER THAN (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH |
| | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN |
| | THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. |
| | IN AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 |
| | PERSONS. |
| | |
| | A) FBC (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION |
| | PLAN. THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL |
| | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A |
| | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION |
| | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL |
| | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING |
| | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR |
| | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE |
| | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE |
| | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT |
| | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE |
| | WITH THE PERMITTED DOCUMENTS. |
| | |
| | B) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. |
| | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD |
| | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) |
| | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY |
| | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED |
| | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED |
| | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED |
| | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. |
| | |
| | C) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT |
| | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED |
| | TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF |
| | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE |
| | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND |
| | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM |
| | BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS |
| | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH |
| | THIS SECTION AND CHAPTER 633 FLORIDA STATUTES. |
| | |
| | D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF |
| | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME |
| | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED |
| | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL |
| | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN |
| | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| | MEETING THE ABOVE CRITERIA. |
| | |
| | E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY |
| | FOR THIS TYPE OF CONSTRUCTION. |
| | |
| | F) NOTE: FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, |
| | PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING |
| | ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE |
| | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR |
| | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN |
| | COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR |
| | THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE |
| | IN BLACK & WHITE. |
| | |
| | G) 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES, |
| | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT |
| | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING |
| | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND |
| | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING |
| | DOCUMENTS BY THE CONTRACTOR. |
| | |
| | H) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED |
| | TELEPHONE INSPECTIONS LINE (561) 805-6700 FOR ALL |
| | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE |
| | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 |
| | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. |
| | |
| | I) 110.8 THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR |
| | THRESHOLD INSPECTORS #25. ASSURE THAT THE DESIGNER HAS |
| | REQUIRED ON THE PLANS OR SPECIFICATIONS ONE MATERIAL, |
| | APPROVED FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND |
| | CEILINGS. |
| | |
| | J) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL |
| | BE HAPPY TO SEND YOU A COPY OF THE CURRENT (OCTOBER |
| | 2018) GUIDELINES AND POLICIES FOR PROJECTS CONCERNING |
| | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS. |
| | |
| | 4) ADDITIONAL PERMITS WILL BE REQUIRED FOR ELECTRICAL, |
| | PLUMBING AND GAS. FBC 105.1 |
| | |
| | 5) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A |
| | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE |
| | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE |
| | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND |
| | KEEP THEM WITH THE SUBMITTALS. |
| | |