| Plan Review Notes For Permit 20021174 |
| Permit Number |
20021174 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-03-03 17:00:55 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW (TENTS) DENIED: | | | | | | 1) FBC B 107.2.1, PLEASE CHANGE MIAMI ADDRESS TO WEST | | | PALM BEACH ADDRESS ON ALL PAGES. | | | | | | 2) FBC B 107.2.1, PLEASE CHANGE THE CONTACTY LIST ON | | | PLANS FROM MIAMI PERSONELL TO WEST PALM BEACH | | | PERSONELL. | | | | | | 3) FBC B 1609.4.3, PLEASE CHANGE THE WIND EXPOSURE AND | | | RECALCULATE THE WIND LOADS FOR THE TENTS ON ALL OF THE | | | SUBMITTED TENT PACKAGES. | | | | | | 4) FBC B 107.2.1, PLEASE PROVIDE THE LAG BOLT SIZES FOR | | | THE DETAIL ON PAGE S-6, BASE PLATE CONNECTIONS TO THE | | | DOCKS. |
|