| Plan Review Notes For Permit 20021048 |
| Permit Number |
20021048 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-03-04 13:04:32 | WALL REPAIR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) EXTERIOR WALLS NEED TO MEET WIND DESIGN REQUIREMENTS | | | PER FBC R301.2.1.1 (FBC BUILDING 1609.1) | | | 2) PLEASE PROVIDE SIGNED AND SEALED DETAILS FROM AN | | | ARCHITECT OR ENGINEER SHOWING ALL MATERIALS AND | | | ATTACHMENTS (TYPE OF FRAMING, HURRICANE STRAPS, | | | EXTERIOR CLADDING ETC.) | | | 3) PLEASE SHOW THE WIND DESIGN CRITERIA USED PER FBC | | | 1603.1 (WIND SPEED AT 170MPH) | | | 4) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF | | | THE REPAIR. | | | 5) IS THE WINDOW BEING REPLACED ? IF SO PLEASE PROVIDE | | | A COMPLETE MIAMI DADE OR FLORIDA STATE PRODUCT | | | APPROVAL. |
|