| 2020-06-02 16:50:39 | 2ND REVIEW FBC-2017 PLUMBING |
| | PERMIT- 20020932 |
| | 6/2/2020 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | COMMENTS FROM THE 1ST REVIEW PRINTED BELOW WILL BE |
| | LABELED AS PASSED OR FAILED PER THE REVISED PLANS. |
| | |
| | 1) PASSED. ON ISOMETRIC (E1.0) DRAWING KITCHEN SINK |
| | CANNOT DISCHARGE INTO WET VET OF A BATHROOM GROUP IT |
| | MUST BE DOWNSTREAM PER THE 2017 FBC SECTION R 3108.1 |
| | HORIZONTAL WET VENT PERMITTED. |
| | |
| | 2) FAILED. PLEASE SHOW THAT SHOWER PAN IS RECESSED IN |
| | PS1.0, IF THE SHOWER PAN IS NOT RECEDED IT WILL REQUIRE |
| | LINING PER 2017 FBC SECTION R 2709.2. |
| | |
| | SHEETS A1 AND S1: THE SHOWER CURB SHALL BE NOT LESS |
| | THAN 2" DEEP WHEN MEASURED FROM THE TOP OF THE CURB TO |
| | THE TOP OF THE DRAIN. IF THE INTENTION IS TO PROVIDE A |
| | RECESSED SHOWER DRAIN, PLEASE SEE SECTION P2709.2 |
| | EXCEPTION 3: THE FINISHED SHOWER DRAIN SHALL BE |
| | DEPRESSED A MINIMUM OF 2" BELOW THE SURROUNDING |
| | FINISHED FLOOR ON THE FIRST FLOOR LEVEL AND THE SHOWER |
| | RECESS SHALL BE POURED INTEGRALLY WITH THE ADJOINING |
| | FLOOR. |
| | |
| | 3) PASSED. THERE ARE 2 E1.0 PAGES PLEASE LABEL TO |
| | DISTINGUISH IE, EP1.1 PER THE WPB AMENDMENTS TO THE FBC |
| | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | 4) PASSED. A SUB PLUMBING PERMIT IS REQUIRED BY A |
| | LICENSED CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB |
| | AMENDMENTS TO THE FBC SEC. 105.1. |
| | |
| | 5) FAILED. HOW IS CABANA GOING TO HAVE HOT WATER, IF |
| | FROM MAIN HOUSE AND LINES ARE BEING RAN UNDERGROUND, |
| | THE HOT ONLY MUST BE INSULATED WITH A MINIMUM R- 3 |
| | INSULATION PER THE 2017 FBC RE SECTION 403.5.3. |
| | |
| | SHOW THE LOCATION OF THE WATER HEATER FOR THE CABANA |
| | AND PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN. |
| | A) SUBMIT MANUFACTURER'S SPECIFICATIONS- P2801.3 FBC |
| | RES. |
| | B) INDICATE HOW ACCESS FOR SERVICE AND REPLACEMENT OF |
| | THE WATER HEATER WILL BE PROVIDED- SECTION P2801.4. |
| | C) SHOW THE PAN DRAIN PIPING RUN AND TERMINATION |
| | LOCATION- P2801.6.2. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |