| Date |
Text |
| 2020-05-05 15:14:20 | |
| | 2ND REVIEW FBC-2017 PLUMBING |
| | PERMIT #20020833 |
| | 5/5/2020 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET A0.0: THE PLUMBING FIXTURE CALCULATION DOES |
| | NOT INCLUDE THE REQUIRED DRINKING FOUNTAIN AND SERVICE |
| | SINK- TABLE 403.3 FBC P. |
| | |
| | 2) A1.0 & P1.1: THERE ARE NO NOTES PROVIDED TO INDICATE |
| | THE SCOPE OF DEMOLITION AND ALTERATIONS PROPOSED FOR |
| | TOILET RM 315- SECTION 107.2.1 WPB. |
| | |
| | 3) P1.1: PROVIDE SANITARY AND WATER RISER DRAWINGS FOR |
| | PLUMBING ALTERATIONS IN TOILET RM 315- SECTION |
| | 107.3.5.1 WPB. SHOW HOW TEMPERED WATER WILL BE PROVIDED |
| | TO THE NEW LAVATORY- SECTION 416.5 FBC P. |
| | |
| | 4) A1.0: TOILET RM 315 DOOR #5 SHALL NOT SWING INTO THE |
| | CLEAR FLOOR SPACE OF THE ACCESSIBLE FIXTURES PER |
| | SECTION 603.2.3 FBC ACC. PLEASE SEE EXCEPTION 2 AND |
| | SHOW COMPLIANCE. |
| | |
| | 5) A1.0, A3.0 & P1.1: THE REQUIRED CLEAR FLOOR SPACE |
| | FOR THE RELOCATED EXAM ROOM SINK IS NOT SHOWN- SEE |
| | SECTIONS 606.2, 305 & 306 FBC ACC. |
| | |
| | 6) A3.0: SHOW THE GRAB BAR HEIGHT FROM THE FINISH FLOOR |
| | TO THE TOP OF THE GRIPPING SURFACE- SECTION 609.4 FBC |
| | ACC. |
| | |
| | 7) A3.0: INDICATE THE TYPE OF SMOOTH, HARD, |
| | NON-ABSORBENT WALL MATERIAL WILL BE USED ON THE WALL |
| | AROUND THE NEW WATER CLOSET TO A HEIGHT OF 4 FT.- |
| | SECTION 1210.2.2 FBC B. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |