| 2020-02-19 15:01:39 | 1) THE PLANS SHOW AN EXISTING GAS METER BUT CITY | | | RECORDS DO NOT SHOW THAT A GAS SYSTEM WAS EVER | | | PERMITTED FOR THIS ADDRESS. ALL EXISTING GAS PIPING, | | | EQUIPMENT AND APPLIANCES MUST BE PERMITTED. WPB AMEND. | | | TO FBC SEC.105.1. | | | 2) SHOW THE LOCATION OF THE TANKLESS WATER HEATER AND | | | THE LOCATION AND DISTANCE OF ANY OPERABLE DOORS OR | | | WINDOWS IN RELATION TO THE TANKLESS WATER HEATER. THE | | | LOCATION OF THE TANKLESS WATER HEATER SHALL COMPLY WITH | | | THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 3) WHERE CONNECTED TO RIGID PIPING, A UNION SHALL BE | | | INSTALLED WITHIN 1 FOOT OF EITHER SIDE OF THE MP | | | REGULATOR. 2017 FBC-FUEL GAS SEC.410.2 (7), 2017 FBC- | | | RESIDENTIAL SEC. G2421.2 (7). | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | |
|