2020-06-15 16:01:25SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE
 ROOFING PRODUCT APPROVAL (18-0919.07) - MAY NEED TO
 PROVIDE ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT
 OR ENGINEER FOR ROOF ZONES 2 AND 3 WHICH MAY REQUIRE A
 HIGHER WIND PRESSURE THAN THE MAXIMUM PRESSURE SHOWN
 FOR THE ROOFING SYSTEM CHOSEN IN THE PRODUCT APPROVAL -
 SEE THE PRODUCT APPROVAL GENERAL LIMITATION NUMBER 7.
 (SIGNED AND SEALED ENGINEERING DOCUMENTS WILL NEED TO
 BE ELECTRONICALLY SIGNED BY THE ARCHITECT OR ENGINEER
 TO BE USED IN ELECTRONIC PLAN REVIEW.
 2) PRODUCT APPROVAL FOR THE CASEMENT WINDOW
 (17-0614.12) REQUIRES SHUTTERS TO MEET IMPACT
 REQUIREMENTS - PLEASE PROVIDE THE COMPLETE MIAMI DADE
 OR FLORIDA STATE PRODUCT APPROVAL FOR THE SHUTTERS.
 3) DRAWINGS SHOULD SHOW THE REQUIRED ATTIC OR RAFTER
 SPACE VENTILATION REQUIREMENTS TO COMPLY WITH FBC
 R806.1 OR SHOW THE DESIGN FOR THE UNVENTED SPACE TO
 COMPLY WITH FBC R806.5
  