| 2020-02-08 06:38:07 | PLAN REVIEW - BUILDING | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SEE ATTACHED GUIDELINES FOR TENTS WITH SPAN OF 40 | | | FEET OR GREATER. | | | | | | 2017 FBC CHAPTER 31 | | | SPECIAL CONSTRUCTION | | | | | | SECTION 3103 | | | | | | **ADDITIONAL REQUIREMENTS | | | FOR TEMPORARY MEMBRANE STRUCTURES (TENTS) WITH A SPAN | | | OF 40 FEET OR GREATER IN ANY DIRECTION: | | | | | | A. PROVIDE DETAILS OF STRUCTURAL CONNECTIONS. INCLUDE | | | BASEPLATE/TIEDOWN DETAILS. | | | B. PROVIDE STRUCTURAL EVALUATION OF STRUCTURE. | | | | | | THESE DOCUMENTS SHALL BE REVIEWED, SIGNED AND SEALED BY | | | A DESIGN PROFESSIONAL. | | | | | | NO EXCEPTIONS | | | | | | |
|