| Date |
Text |
| 2020-03-19 09:45:24 | 1ST REVIEW FBC-2017 PLUMBING |
| | PERMIT #20020232 |
| | 3/19/20 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET P1: WATER HAMMER ARRESTORS ARE REQUIRED FOR |
| | THE DISHWASHER AND WASHING MACHINE PER SECTION P2903.5 |
| | FBC RES. |
| | |
| | 2) P1: THE WATER SUPPLY TO THE DISHWASHER SHALL BE |
| | PROTECTED AGAINST BACKFLOW BY AN AIR GAP OR BACKFLOW |
| | PREVENTER- SECTION P2717 FBC RES. |
| | |
| | 3) P1: PROVIDE THE CLEAR OPENING WIDTH OF THE SHOWER |
| | DOORS IN THE MAIN HOUSE AND THE ACCESSORY BUILDING- |
| | SECTION P2708.1.1 FBC RES. |
| | |
| | 4) P1: PLEASE INCLUDE THE COMBUSTION AIR CALCULATIONS |
| | FOR THE WATER HEATER- SECTION G2407.5.1 FBC RES, AND |
| | PROVIDE THE CORRECT CODE SECTION ON THE PLAN. |
| | |
| | 5) P1: PROVIDE THE MAKE AND MODEL OF THE GAS WATER |
| | HEATER ON THE PLAN AND SUBMIT MANUFACTURER'S |
| | SPECIFICATIONS- SECTION G2448.1 FBC RES. IF THE |
| | APPLIANCE IS A DIRECT VENT PLEASE SHOW THE VENT AND AIR |
| | INTAKE DUCT RUNS AND TERMINATION LOCATIONS ON THE PLAN- |
| | SECTIONS G2427.2.1 & G2427.8(3) FBC RES. |
| | |
| | 6) P1: INDICATE HOW HOT WATER IS BEING PROVIDED TO THE |
| | SINK AND SHOWER IN THE ACCESSORY BUILDING- P2801.1 FBC |
| | RES. |
| | |
| | 7) P1: THE ENERGYGAUGE COMPLIANCE REPORT FORM R405-2017 |
| | INDICATES A 40 GALLON STORAGE WATER HEATER WHICH IS NOT |
| | SHOWN ON THE PLAN- SECTION R403.5.6 FBC RES. |
| | |
| | 8) BECAUSE THERE ARE TWO SEPARATE DWELLINGS TO BE |
| | CONSTRUCTED ON THE SAME LOT, PLEASE BE ADVISED THAT |
| | INSTALLATION OF AN RPZ-TYPE BACKFLOW PREVENTER WILL BE |
| | REQUIRED FOR THE WATER SERVICE PER THE CITY OF WEST |
| | PALM BEACH CROSS CONNECTION MANUAL. |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |