| Plan Review Notes For Permit 20020093 |
| Permit Number |
20020093 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-02-06 15:30:58 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- ROOF TILE FL 7804-R10 SUBMITTED. CLEARLY SPECIFY | | | TILE FASTENING METHOD AS REQUIRED BY CITY POLICY FOR | | | ALL ROOFFING PERMITS TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R3012.1 FBC-RESIDENTIAL. IF | | | SPECIFYING SCREWS, THEN SPECIFY THE NUMBER AND SIZE OF | | | SCREWS TO BE USED FOR ALL ROOF ZONES. IF USING | | | ADHESIVE, THEN PROVIDE PRODUCT APPROVAL AND CLEARLY | | | MARK PADDY SIZE. | | | NOTE: KEEP IN MIND THAT THIS BUILDING IS LOCATED IN | | | WIND EXPOSURE D. PROPOSED FASTENING NEEDS TO MEET THE | | | REQUIRED ROOF TILE RESISTANCE VALUE FOR ALL ROOF ZONES | | | BASED ON THE BUILDING EXPOSURE AND BUILDING HEIGHT. | | | PROVIDE INFORMATION SHOWING THE ROOF TILE RESISTANCE | | | VALUE ON ALL ROOF ZONES. | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | | COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|