Plan Review Notes
Plan Review Notes For Permit 20011288
Permit Number 20011288
Review Stop P
Sequence Number 2
Notes
Date Text
2020-05-05 11:22:202ND REVIEW FBC-2017 PLUMBING
 PERMIT #20011288
 5/5/20
  
 CODES IN EFFECT.
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P1 & P2: PROVIDE A CLEANOUT AT THE POINT
 WHERE THE GUEST HOUSE BUILDING DRAIN EXITS THE
 STRUCTURE AND CONNECTS TO THE SEWER PIPE- SECTION
 P3005.2.3 FBC RES.
  
 2) P1 & P2: PROVIDE A VENT FOR THE GUEST ROOM BATH
 GROUP. IT APPEARS BY THE DRAWING THAT A VENT STACK
 CONNECTED TO THE LAV. DRAIN WOULD BE A GOOD LOCATION-
 SEE SECTION P3108.1 HORIZONTAL WET VENT- FBC RES.
  
 3) P2: PLEASE SHOW THE WYE FITTING DRAIN CONNECTIONS
 POSITIONED IN THE DIRECTION OF FLOW- SECTION P2608.1
 FBC RES.
  
 4) P2: SHOW THE REQUIRED 2" TRAP AND 3" BRANCH DRAIN
 FOR THE WASHING MACHINE- P3201.7 FBC RES & 406.2 FBC P.
  
 5) P1 & P2: SHOW THE DISHWASHER LOCATIONS AND DRAIN
 CONNECTION- P2717.2 FBC RES.
  
 6) P1 & P2: THE SHOWER PANS SHALL COMPLY WITH SECTION
 P2709.2 FBC RES, AND THE SHOWER VALVES SHALL COMPLY
 WITH SECTION P2708.2 FBC RES. PLEASE PLACE NOTES AND/OR
 DETAILS ON THE PLAN TO SHOW COMPLIANCE.
  
 7) INSTALLATION OF AN RPZ BACKFLOW PREVENTER IS
 REQUIRED FOR THE WATER SERVICE TO THE TWO SEPARATE
 DWELLINGS ON THE SAME LOT. A FL. LICENSED PLUMBING
 CONTRACTOR CERTIFIED FOR INSTALLATION SHALL SUBMIT A
 SEPARATE PERMIT APPLICATION TO BE APPROVED BY THE WPB
 BUILDING AND UTILITIES DEPARTMENTS.
  
 8) P1: ACCORDING TO THE ENERGY COMPLIANCE SUBMITTAL AND
 THE ELECTRIC PANEL SCHEDULES, GAS-FIRED TANKLESS WATER
 HEATERS ARE TO BE INSTALLED FOR EACH BUILDING.
 A) SHOW THE LOCATIONS OF THE UNITS ON THE PLAN ALONG
 WITH ANY OTHER GAS-FIRED APPLIANCES EITHER NEW OR
 EXISTING- SECTION 107.2.1 WPB.
 B) PROVIDE WATER HEATER EQUIPMENT SCHEDULES ON THE PLAN
 AND SUBMIT MANUFACTURE'S SPECIFICATIONS AND
 INSTALLATION INSTRUCTIONS FOR THE WATER HEATERS AND ALL
 NEW APPLIANCES- SECTION 107.2.1 WPB.
 C) PROVIDE GAS ISOMETRIC DRAWINGS FOR EACH BUILDING
 SHOWING THE TYPES AND SIZES OF GAS PIPING, DELIVERY
 PRESSURES, TOTAL DEVELOPED LENGTH OF THE PIPING RUNS,
 LENGTHS OF ALL CUT SECTIONS OF PIPING, LOCATIONS OF
 REGULATORS, UNIONS, DRIP LEGS, AND PIPE CONNECTION
 FITTINGS- SECTIONS G2413.4.1, G2413.4.2, G2413.3,
 G2413.4, AND TABLES G2413.4(1) THROUGH G2413.4(21) FBC
 RES.
 D) SHOW LOCATIONS OF REQUIRED VENTS AND PROVIDE VENTING
 DIAGRAMS THAT INDICATE THE TYPE AND SIZE OF VENT, TOTAL
 RUN LENGTHS, TERMINATION LOCATIONS, AND SUPPORT
 DETAILS- G2426- G2429 FBC RES.
 E) PLEASE NOTE A SEPARATE PERMIT IS REQUIRED FOR THE
 GAS PIPING INSTALLATION- SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  