| 2020-08-22 07:34:33 | PLAN REVIEW - FUEL GAS |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER BUILDING - PX3169 |
| | PLANS EXAMINER 1&2 FAMILY - SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 FBC RES-FUEL GAS CHPT. 24 |
| | |
| | 2ND REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS FROM 1ST REVIEW AND |
| | RE-SUBMIT |
| | |
| | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| | SATISFACTORILY ARE MARKED AS CORRECTED. |
| | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED |
| | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN |
| | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER |
| | PREVIOUS COMMENTS. |
| | |
| | 1ST REVIEW COMMENTS: |
| | |
| | 1) SHT. P-2 - THE GAS CALCULATION NOTES SHOW A BTU LOAD |
| | OF 607,000 BTU'S BUT THE PLANS SHOW A TOTAL BTU LOAD OF |
| | 207,000 BTU'S. CLARIFY. (GAS CALCULATIONS ON PLAN PAGE |
| | P-2 INDICATE POOL HEATER AS EXISTING. PER NOTE BELOW, |
| | THERE IS NO RECORD OF THE POOL HEATER BEING PERMITTED. |
| | INCLUDE THE POOL HEATER ON ISO AND IDENTIFY LOCATION ON |
| | GAS PLAN. SHOW PIPE TYPE, SIZE AND LENGTH. PROVIDE |
| | MANUFACTURERES INSTALLATION INSTRUCTIONS) |
| | |
| | 2) LIST THE BTU LOAD OF EACH APPLIANCE ON THE SYSTEM. |
| | REFER TO THE 2017 FBC-FUEL GAS SECS.401.8, 402.2, AND |
| | TABLES 402.4 (1) THRU 402.4 (37) OR 2017 FBC-RES. SEC. |
| | G2413.3, G2413.4 AND TABLES G2413.4 (1 ) THROUGH |
| | G2413.4 (21). (SEE COMMENTS ABOVE) |
| | |
| | 3) SUBMIT MANUFACTURERS SPECIFICATION SHEETS / |
| | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY |
| | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND |
| | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 |
| | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED |
| | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS |
| | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF |
| | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. |
| | (MANUFACTURERS SPECIFICATIONS NOT SUBMITTED FOR REVIEW) |
| | |
| | NOTE: CITY RECORDS ONLY SHOW A GAS PERMIT FOR THE |
| | TANKLESS WATER HEATER AND THE RANGE. ANY OTHER GAS |
| | APPLIANCES THAT ARE CURRENTLY ON THIS SYSTEM MUST BE |
| | PERMITTED. (POOL HEATER SHALL BE PERMITTED AND |
| | INSPECTED. SEE COMMENTS ABOVE) |
| | |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | PLUMBING PLAN REVIEW |
| | 561-805-6692 |
| | [email protected] |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| | REVIEWED SHEETS DETACHED. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |
| | |