| Plan Review Notes For Permit 20011193 |
| Permit Number |
20011193 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2020-02-06 11:16:35 | FLOORING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - | | | 1) THE BUILDING AT 1617 N FLAGLER HAS A 6" SLAB - I | | | NEED AN "ACOUSTICAL LABORATORY TEST REPORT" THAT SHOWS | | | THE TEST DESCRIPTION FOR A 6" THICK SLAB ( NO CEILING | | | ). CONTACT THE UNDERLAYMENT MANUFACTURE OR THE STORE | | | THAT YOU ARE GETTING THE UNDERLAYMENT (PROFLEX) FROMAND | | | ASK FOR THE "ACOUSTICAL LABORATORY TEST REPORT". NEED | | | AN IIC (ASTM E989-06) AND AN STC (ASTM E90) OF 50 OR | | | HIGHER. IF PROFLEX DOESN'T HAVE THE TEST REPORT PLEASE | | | TRY ANOTHER PRODUCT - - SEE FBC 1207 | | | |
|