| Date |
Text |
| 2020-01-30 10:22:24 | REVISION BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE. |
| | |
| | 1- NEW STOREFRONT WAS NO PART OF THE MASTER PERMIT |
| | 19021006. PLANS NEED TO BE REVISED BY THE DESIGNER OF |
| | RECORD. PLANS NEED TO SHOW THE PROPOSED STOREFRONT |
| | LAYOUT. DOOR HARDWARE, ETC. PROVIDE SIGNED AND SEALED |
| | REVISED PLANS. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 2- ORIGINAL PERMIT PACKAGE 19021006 WAS SUBMITTED |
| | DIGITALLY. ANY REVISED PLANS NEED TO BE SUBMITTED THE |
| | SAME WAY AS THE ORIGINAL PERMIT PACKAGE TO KEEP |
| | CONSISTENCY AND PROPER RECORDS RETENTION. SEC. |
| | 107.2.1.3 CITY AMENDMENTS. |
| | |
| | 3- NEW STOREFRONT WAS NO PART OF THE MASTER PERMIT |
| | 19021006. THE ADDITIONAL VALUE FOR THE NEW STOREFRONT |
| | NEEDS TO BE INCLUDED IN THIS REVISION. PROVIDE VALUE |
| | FOR NEW STOREFRONT. SEC. 109.3 CITY AMENDMENTS. |
| | |
| | 4- STOREFRONT PRODUCT APPROVALS SUBMITTED. IDENTIFY |
| | GLAZING/ MULLIONS. FOR ALL PRODUCTS WITH GLAZING, |
| | PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF |
| | GLAZING, MULLION INFORMATION IF REQUIRED, ATTACHMENTS |
| | AND ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2017 |
| | FBC-B 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL |
| | BE INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURERS |
| | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE |
| | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED |
| | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. |
| | |
| | 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | 6- IT IS NO CLEAR WHAT PRODUCT APPROVALS ARE GOING TO |
| | TO BE USED FOR THE NEW STOREFRONT. |
| | THERE ARE DIFFERENT NOA'S SUBMITTED. SOME ARE IMPACT |
| | RATED AND SOME ARE NOT. PROVIDE ONLY THE PRODUCT |
| | APPROVALS THAT ARE GOING TO BE USED. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | NOTE: GLAZING IS REQUIRED TO HAVE IMPACT PROTECTION. IF |
| | SELECTED PRODUCT APPROVALS ARE NO IMPACT, THEN COMPLETE |
| | INFORMATION WILL BE REQUIRED, INCLUDING SHUTTERS |
| | PRODUCT APPROVAL AND INSTALLATION SCHEDULE. |
| | |
| | 7- PRODUCT APPROVALS SUBMITTED ARE NOT LEGIBLE. THE |
| | INSTALLATION DRAWINGS SUBMITTED WITH THE NOA'S ARE NOT |
| | LEGIBLE. DRAWINGS ARE CUT INTO PIECES. PROVIDE FULL |
| | DRAWINGS THAT WILL FIT THE PAGE. FOR EXAMPLE IN |
| | LANDSCAPE FORMAT. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | |
| | WHEN RESUBMITTING PLANS A TRANSMITTAL LETTER LISTING |
| | THE ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION |
| | OF THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |